Immunity and Emissions Testing There are 35 products.

per page
Showing 25 - 35 of 35 items
    • Broad Frequency Range of 1 MHz - 500 MHz
    • Measures currents on 50 Hz, 60 Hz and 400 Hz powerlines
    • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 4 to 16 dB
    • Transfer Impedance: 16 to 31 dBW
    • Max Input Power: 200 Watts
    Typically In Stock
    Request Quote/More Info
    • Max EUT Size: (410 x 410 x 310mm) (16.14 x 16.14 x 12.20in.)
    • MAX EUT dimension for uniform-area: (167 x 167 x 167mm) (6.57 x 6.57 x 6.57in.)
    • For all Phases of EMC Testing
      • Design Qualification 
      • Pre-Compliance 
      • Full Compliance IEC 61000-4-3 ANSI C63.4
    Typically In Stock
    Request Quote/More Info
    • Max EUT Size: (1110 x 1110 x 990mm) (43.7 x 43.7 x 38.97in.)
    • Max EUT dimension for uniform-area: (500 x 500 x 500mm) (19.68 x 19.68 x 19.68in.)
    • Emissions and immunity testing in a single, shielded environment
    • Meets basic standard: IEC/EN 61000-4-20
    • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
    • Meets standards for immunity testing: EN 60118-13
    • Ideal for design qualification and pre-certification
    In Stock
    Request Quote/More Info
    • Max EUT Size: (930 x 930 x 830mm) (36.31 x 36.61 x 32.67in.)
    • EUT dimension for uniform-area: (416 x 416 x 416mm) (16.37 x 16.37 x 16.37in.)
    • Emissions and immunity testing in a single, shielded environment
    • Meets basic standard: IEC/EN 61000-4-20
    • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
    • Meets standards for immunity testing: EN 60118-13
    • Ideal for design qualification and pre-certification
    In Stock
    Request Quote/More Info
    • Meets IEC/EN 61000-4-8 standard
    • Suitable for 50/60 Hz power lines
    • Continuous, Intermittent and Manual mode operation
    • Up to 170 A (continuous) and 1200 A (5 sec.) output current
    • LCD display, functional keys and Led indicators
    • Automatic level adjustment
    • Interlock key for additional safety
    • User port to drive external switches
    • Different loop antennas available (option)
    In Stock
    Request Quote/More Info
    • Integrated signal generator 4 kHz to 1 GHz
    • 3 power meter inputs 4 kHz to 1 GHz
    • Integrated class A power amplifier module:
      Multiple EUT monitoring options
      • 80 W, 150 kHz to 230 MHz
    • 5,7“ TFT color display
    • Internal, menu-based control software
    • Basic remote control software and report generator included
    • Optically decoupled remote control
    • Whisper mode
    In Stock
    Request Quote/More Info
    • Integrated signal generator 9 kHz to 1 GHz
    • 3 power meter inputs 9 kHz to 1 GHz
    • Integrated power amplifier module for different applications
    • Multiple EUT monitoring options
    • Optional built-in amplifier up to 75 watts (150 kHz - 230 MHz)
    • Meet IEC 61000-4-6,  IEC 61000-4-3, IEC 61000-4-20, IEC 61000-4-21 
    • Meet Mil-STD 461 CS114
    In Stock
    Request Quote/More Info
    • 80 MHz to 40 GHz Frequency Range 
    • Minimum Chamber Performance:
      • 6 dB Reflectivity Loss From 80 MHz to 250 MHz
      • 10 dB Reflectivity Loss Above 250 MHz 
    • Conducted Emissions
    • Conducted Susceptibility
    In Stock
    Request Quote/More Info
    • Frequency Range: 1 MHz - 1 GHz
    • Transfer Impedance: 0 to 24 dBW
    • Current: 200 Amps Max
    • Individually Calibrated (Transfer Impedance calibration included)
    • High Current Capability
    • Split Type Clamp-on Design
    Typically In Stock
    Request Quote/More Info
    • Broad High Frequency Response: 1 MHz - 400 MHz
    • Induce RF currents in accordance with MIL-STD 461 susceptibility testing
    • Measures currents on 50 Hz, 60 Hz and 400 Hz power lines
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 4 to 22 dB
    • Max Input Power: 100 Watts CS
    Typically In Stock
    Request Quote/More Info
    • Broad Frequency Range of 10 KHz to 100 MHz
    • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    • Current injection source as well as a sensitive monitoring probe.
    • Insertion Loss: 8 to 30 dB
    • Max Input Power: 100 Watts
    • Connector: N-type, Female
    • Aperture: 1.5" (38mm)
    • Diameter: 4.25" (108mm)
    • Weight: 4.2 lbs (1.9 kg)
    Typically In Stock
    Request Quote/More Info
Showing 25 - 35 of 35 items