Viewed products
Max EUT Size: (930 x 930 x 830mm)...
New
Warning: Last items in stock!
Availability date:
A GTEM (Gigahertz Transverse Electro Magnetic) cell is a test site for efficiently performing both radiated immunity and emissions testing in a single, controllable and shielded environment. Compared to other test sites, GTEM testing is faster with high accuracy and excellent reproducibility. In principle, the GTEM cell is a coaxial line expanding pyramidally and having an impedance of 50 Ω. At its end, the line is terminated by a combination of termination resistors and RF absorbers designed and constructed to match the above mentioned impedance. The GTEM 1250 has a maximum septum height of 1250 mm and is suitable for emissions and immunity testing.
Parameter | Value |
---|---|
Max. septum height | 1000 mm |
Septum height at marker position | 866 mm |
Dimension (LxWxH) | 4.95 x 2.54 x 2.30 m |
Weight | approx. 790 kg |
Height H1 of cell corpus | 1.73 m |