EMI Current Probes/Monitors

EMI Current Probes/Monitors are broadband RF devices, used to monitor current on data and power lines. While The EMC Shop stocks and uses them for EMC applications, many engineers will use them during product design and for other general testing purposes.

 

Typically used in tantum with bulk current injection (BCI) probes. A broadband EMI current probe is used downstream to evaluate and monitor changes in characteristics once a low level RF/high frequency current was injected into the line or cable bundle. Typical applications include Mil-STD-461 CS101, CS102, RTCA-DO-160 and EN/IEC 61000-4-6.

 

Get Application Support, Pricing, Lead Time and More: Contact Form

EMI Current Probes/Monitors There are 39 products.

Subcategories

  • RF Current Probe Calibration Fixtures

    Order RF Current Probe Calibration Fixtures for monitoring probes. The EMC Shop is the only online store for electromagnetic compliance test equipment and accessories.

    Get Application Support, Pricing, Lead Time and More: Contact Form

per page
Showing 25 - 36 of 39 items
    • Measures currents on 50 Hz, 60 Hz and 400 Hz powerlines
    • 400 Amps Max (up to 400 Hz); 5,000 Amps Pulse
    • Transfer Impedance: -63 to -28 dBW
    • Suitable for IEC 61000-4-16, IEC 61000-4-19 Annex C, SAE J1113-2, ISO 11452-8, DO 160D/E Section 18 and MIL-STD-461 D/E CS101, CS109 and RS101
    • Individually Calibrated (Transfer Impedance calibration included)
    • Split Type Clamp-on Design
    Typically In Stock
    Request Quote/More Info
    • Rentals Ship Immediately
    • In Stock, Calibrated and Ready to Ship
    • Prices are on a Per Month Basis

    Purchase Pearson 101

    Typically In Stock
    Request Quote/More Info
    • Frequency Range 10 kHz to 400 MHz
    • Includes:
      • Pearson 8700i Current Injection Probe
      • Pearson 8705 Current Monitor
      • Pearson F-3 Calibration Jig
    • MIL-STD-461 CS114, CS115, CS116
    • DO-160 Section 21, rf CE (8705C)
    • AIAA S-121 Radio Frequency CS
    • NASA GSFC EMI Specs CE03, Bulk current emission
    • Automotive Chrysler Radio Frequency CE
    • John Deere Radio Frequency CE
    • BMW Radio Frequency CE
    • IEC / EN 61000-4-6
    • TR-102323 Radio Frequency CS
    In Stock
    Request Quote/More Info
    • 1 kHz – 250 MHz Frequency Range
    • For laboratory and field testing
    • Probe has a small outer diameter
    • Approximately 71 mm with an internal diameter of 32 mm
    • DBΩ (Nominal): Ø
    • ZTΩ (Nominal): 1
    • Calibration Fixture: FCC-MPCF-3-32/71/19
    • DC to 400 Hz: 100 amperes
    In Stock
    Request Quote/More Info
    • 10 kHz – 500 MHz Frequency
    • For laboratory and field testing
    • RF current range is 50 amperes CW and 100 amperes peak pulse with a duty cycle of 0.1
    • Maximum primary powerline current is 350 amperes from DC – 400Hz
    • ZtΩ1: 8
    • dBΩ1: 18
    • DC to 400 Hz: 350 amperes
    • Peak Pulse Current2 : 100 amperes
    In Stock
    Request Quote/More Info
    • 10 kHz to 400 MHz Frequency Range
    • Maximum RMS Current 4 A
    • MIL-STD-461 CS114, CS115, CS116
    • Calibration Fixture F-3

    To Purchase Pearson 8705C

    In Stock
    Request Quote/More Info
    • Frequency: 10 kHz – 500 MHz
    • Connector: Type-N
    • Internal diameter: 32mm
    • External diameter: 71mm
    • Height: 19mm
    Inquire for Qty In Stock
    Request Quote/More Info
    • 10 KHz to 500 MHz
    • Pulse Currents up to 100 Amperes
    • Split Type Clamp-on Design
    • High Current Capability
    • Individually Calibrated (Transfer Impedance calibration included)
    • Three Year Warranty
    In Stock
    Request Quote/More Info
    • As required in IEC/EN 61000-4-6
    • Suitable for BCI testing per ISO 11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards
    • Active/passive operation for wide dynamic range
    • Suitable for NSG 4070
    • Ruggedly designed
    Rentals in Stock
    Request Quote/More Info
  • In Stock
    Request Quote/More Info
    • Frequency: 10 kHz – 250 MHz
    • Connector: Type-N
    • Internal diameter: 32mm
    • External diameter: 71mm
    • Height: 19mm
    Inquire for Qty In Stock
    Request Quote/More Info
    • Frequency Range: 1 MHz - 1 GHz
    • Transfer Impedance: 0 to 24 dBW
    • Current: 200 Amps Max
    • Individually Calibrated (Transfer Impedance calibration included)
    • High Current Capability
    • Split Type Clamp-on Design
    Typically In Stock
    Request Quote/More Info
Showing 25 - 36 of 39 items