CDN-M3-16A Coupling & Decoupling Network

New

  • Coupling / Decoupling Network
  • 16 Amps 
  • 150 kHz to 230 MHz

More details

Request Quote/More Info

PDF Downloads

Test Equipment Description

The CDN-M3-16A is a Coupling Decoupling Network for conducted immunity testing according to IEC 61000-4-6. The  CDN-M3-16A is compliant with IEC 61000-4-6 Annex D2 and is designed to inject common mode disturbance signals in the frequency range from 150 kHz to 230 MHz into unscreened AC and DC power supply lines.

CDN-M3-16A Coupling & Decoupling Network Specifications 

  • Maximum supply voltage: 300V AC, 600V DC
  • Maximum current: 16A
  • Frequency range: 150 kHz – 230 MHz
  • Maximum RF input power: 6.5W CW
  • Maximum RF input voltage: 32 V
  • Common mode impedance:
  • 150 kHz – 24 MHz: 150 Ω ± 20 Ω
  • 24 MHz – 80 MHz: 150 Ω + 60 Ω / – 45 Ω
  • 80 MHz – 230 MHz: 150 Ω ± 60 Ω
  • Voltage Division Ratio: 150 kHz – 80 MHz: 9.5 dB ± 1 dB
  • 80 MHz – 230 MHz: 9.5 dB + 3 dB / – 2 dB
  • RF input connector: N – female
  • EUT / AE connectors: 4 mm banana safety jacks, 4mm slots in base plate for GND connection
  • Housing material: powder coated aluminium, stainless steel base plate
  • Dimensions: 12 x 6 x 6 inches
  • Weight: 2.2 lbs

Associated EMC Test Equipment