CISPR Standards

Quick Links

Information

Viewed products

Teseq CDN M016 Switchable 16 Amp Coupling/Decoupling Network

New

  • Coupling/Decoupling Network (CDN) CDN M Type
  • Designed for IEC/EN 61000-4-6 Conducted RF Immunity Testing
  • CDN M016 switchable M2 or M3 (2 or 3 power lines)
  • Types with 4 mm banana sockets
  • 150kHz to 230 MHz (300 MHz)
  • Rent the Teseq M016 CDN

More details

In Stock

Request Quote/More Info

Specifications

Voltage RatingAC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec
Frequency Range150 kHz to 230 MHz
RF ConnectorBNC 50 Ω
Standards MetIEC/EN 61000-4-6
Mains & EUT Connections4 mm banana
Common Mode Impedance150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
Current Rating16 Amps
Application/Test Typeswitchable 2 or 3 power lines, (L+N or L+N+PE)
Insertion LossLess than 0.1 dB
RF Input Voltage30 Volts (Max)
Decoupling of Common Mode Disturbance150 kHz: Greater than 30 dB1.5 MHz: Greater than 60 dB30 MHz: Greater than 40 dB230 MHz: Greater than 20 dB
Voltage Division Factor150 kHz to 80 MHz: 9.5 dB ±1 dB80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dB
Dimensions3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)
Weight3.3 Lbs (1.5 kg)

Test Equipment Description

Compatible with:

The EMC Shops RFCI-75 RF Conducted Immunity Generator, 100 kHz - 400 MHz

Teseqs NSG 4070 Test System for Conducted & Radiated Immunity

How to Rent the Teseq CDN M016:

  • Click "Add to Cart" above
  • Register or Check Out as a Guest
  • Select Shipping Method (use "My Account" and input your account # and method)
  • Order Confirmation and Tracking Info Follows

About the Teseq CDN M016:

IEC/EN 61000-4-6 specifies the design and performance of a range of coupling/decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq offers an extensive range of CDNs which fully comply with the requirements of the standard and provide a simple and reliable method of injecting RF energy into the equipment under test (EUT).

Whilst the published standard only specifies the performance of CDN from 150 kHz to 80 MHz, most of Teseq CDNs are specially designed to give the same performance to a wider frequency range. This is required by some product specific standards. Each CDN is also useable for emission testing. Special types meet the requirements of CISPR 15 or can be used as impedance stabilization network (ISN) defined in CISPR 22.

Included with the Teseq CDN M016:

  • M016 CDN
  • QTY 2 CAL U100B
  • SAR MA31
  • QTY 2 SAR M300
  • SAR M116
  • A 50-N
  • NIST Calibration with Data
  • Carrying Case
  • User Manual

All those part numbers confusing? Those are all the cal adapters required to get up and running