EFT Testing

 

EFT testing is a routine test  of electronics to determine immunity to micropulse phenomena that occurs along the power and data lines inside facilities, homes and vehicles. It can occur when a light switch is engaged, or a product holding a charge is plugged into the wall. Similarly, PoE can be a source for electrical fast transients along data lines, such as ethernet cables. For the physics, mathematical equations as to why EFT events exist, go back to Google, there are many in depth articles. Most of our customers are satisfied with the general understanding of the test, then more importantly, passing it for compliance and/or improving their product.

 
Pass/Fail Criteria for EFT Testing

The test sequences, clearly defined in IEC/EN 61000-4-4, are a variety of electrical fast transients delivered in bursts, in intervals over the course of several minutes. Most product specific standards give guidance as to what the failure criteria is. IE EN 55024 (ITE equipment) are determined by manufacturer, customer and best practice. This could range from allowing a soft reset during the EFT test sequence, a delay in processing or a system shut down. Usually, burning smells, melted plastic or a good old fashioned fire will be considered a fail. 

EFT Testing Procedure

Most modern EFT transient generators have test sequences pre-programmed, with the ability to manipulate test parameters such as pulse frequency and duration. The testing procedure constitutes:

  • Reading the test standard, manual and developing a test plan

  • Setting your product near to the EFT generator, while allowing the user to safely monitor the product.

  • Coupling your product into the generator

  • Starting the test sequence

  • Identify susceptibility areas and narrow down testing to troubleshoot and debug

  • Generate a test report

EFT Test Setup and Overview

Meet Electrical Fast Transient/Burst immunity test standards like IEC/EN 61000-4-4 with stand alone EFT/burst simulators.

EFT Testing There are 47 products.

per page
Showing 25 - 36 of 47 items
    • 3 Phase Coupler suitable for DUT up to:
      • 32 Amps, 3x 690 Volts AC
      • 32 Amps, 270 Volts DC
    • Voltage up to 4.8 kV
    • Meets Conducted Immunity Standards:
      • ANSI/IEEE C62.41
      • IEC/EN 61000-4-4
      • IEC 60601-1-2
      • IEC 61326
      • IEC 61850-3
    • Pulse verification acc. to Edition 3 on each coupling path
    In Stock
    Request Quote/More Info
  • Typically In Stock
    Request Quote/More Info
    • Combined coupler for EFT/Burst and Surge testing
    • Surge as per ANSI/IEEE C62.41 (models CNI 501Bx only, other couplers on request)
    • LEDs indicate active mode and coupling
    • Automatic selection of Surge impedance
    • Fully remote controlled by EM TEST generators
    • Meet requirements up to 1,000V DC
    In Stock
    Request Quote/More Info
    • Combined coupler for EFT/Burst and Surge testing
    • Surge as per ANSI/IEEE C62.41 (models CNI 501Bx only, other couplers on request)
    • LEDs indicate active mode and coupling
    • Automatic selection of Surge impedance
    • Fully remote controlled by EM TEST generators
    • Meet requirements up to 1,000V DC
    In Stock
    Request Quote/More Info
    • With 3-ph coupler, AC: 3x 440V/ 50A, DC: 270V/ 50A
    • 10,000 Pulses/sec.
    • 4.8kV Burst Voltage
    • Spike Frequency up to 1MHz
    • Built-in 1ph or 3ph coupler up to 50A
    • Pulse Verification acc. to Ed.3 on each coupling path

    Applications:

    • Industry
    • Medical
    • Broadcast
    • Residential
    In Stock
    Request Quote/More Info
    • With 3-phase coupler; 3 x 440V/32A
    • Standalone Tester
    • 7,000V Burst voltage
    • Spike frequency 1MHz
    • Built-in 1ph or 3ph coupler
    • USB (optical link) and GPIB interface
    • Standard Test routines

    Applications:

    • Industry
    • Medical
    • Broadcast
    • Residential
    • Telecom
    • Components
    In Stock
    Request Quote/More Info
    • With 3-ph coupler, AC: 3x 440V/ 32A, DC: 270V/ 32A
    • 10,000 Pulses/sec.
    • 4.8kV Burst Voltage
    • Spike Frequency up to 1MHz
    • Built-in 1ph or 3ph coupler up to 50A
    • Pulse Verification acc. to Ed.3 on each coupling path

    Applications:

    • Industry
    • Medical
    • Broadcast
    • Residential
    In Stock
    Request Quote/More Info
    • 100 Day Warranty
    • Fresh Traceable Calibration Certificate with Data
    • Order online now
    • Voltage Range: 0.10 to 4.5 kV
    • Built in Single Phase Coupler
    Typically In Stock
    Request Quote/More Info
    • Suitable for pre-compliance to IEC 61000-4-4
    • Built-in 3 Phase / 30 Amp Coupler
    • Easily Programmable
    • 100 Day Warranty
    • Fresh NIST calibration
    In Stock
    Request Quote/More Info
    • Monthly Rental - Ships Immediately
    • Ideal for 3 Phase DUT IEC 61000-4-4 testing
    • For AC and DC up to 100 Amps per channel
    • EUT Supply voltage to 690 VAC and 1000 VDC
    • Parallel channels for Single Phase/DC application and increase current capability
    • Compatible with all burst/EFT generators up to 8 kV
    • Built-in temperature monitor
    Typically In Stock
    Request Quote/More Info
    • Compatible with Teseq's NSG 3040, NSG 3060 systems
    • Use with Teseq CAS 3025
    • Complies with IEC 61000-4-4 Ed 2.0 2004
    • Complies with IEC 61000-4-4 Ed 3.0 2012
    • Safety cover with interlock
    • Calibration kit per IEC 61000-4-4 Ed 3.0 2012
    In Stock
    Request Quote/More Info
    • Industry Best Warranty on Used Test Equipment
    • Try before you bur or rent this Keytek 8kV EFT System
    • System Configuration:
      • E103 Controller (fiber-interface for remote control)
      • E421 EFT/Noise Burst Simulator to 8 kV (IEC 61000-4-4)
      • E4554 Burst Coupling up to 8 kV
      • Input voltage: 100V to 240VAC
      • Input Current: 3.5A at 100 V; 1.5A at 240 V
      • User Manual
      • Fresh Calibration Certificate
      • 10% off Calibration Service for Life
    In Stock
    Request Quote/More Info
Showing 25 - 36 of 47 items