Combination Wave/Surge Generators

 

Combination wave generators are used to meet IEC/EN 61000-4-5ANSI (IEEE) C62.41 and other surge immunity standards. The EMC Shop has a wide selection of combination wave generators and associated coupling/decouping networks in stock.

 

Also See - IEC 61000-4-5 Surge Immunity Testing

Also See - IEC 61000-4-4 EFT Testing

Also See - IEC 61000-4-6 Testing and Setup

Video Overview - Surge4-5 Combination Wave Generator

Getting Started witha Combination Wave Generator

Combination wave/surge generators are typically benchtop, but heavy equipment. Testing on data and three phase power lines require additional coupling/decoupling networks. Pre programmed test sequences for surge immunity allows you to begin testing once coupling in your EUT and properly grounding the test setup.

Combination Wave/Surge Generators There are 51 products.

Subcategories

  • 4 kV Surge Generators

     

    BCI Testing & Equipment           Automotive EMI/EMC Testing            EFT/Burst Generators           LISN's

     

    Combination Wave/Surge generators are required to meet IEC/EN 61000-4-5, ANSI (IEEE) 62.41 and other conducted immunity standards requiring a surge EMC test. The EMC Shop stocks all types of Combination Wave/Surge generators for compliance and pre-compliance testing. Rent or buy Combination/Surge generators for individual tests or multifunction generators to complete an assortment of tests in a compact solution. Most systems can be easily upgraded to include additional tests as required.

    Get Application Support, Pricing, Lead Time and More: Contact Form



    Combination Wave/Surge generators are typically benchtop, but heavy equipment. When doing testing on three phase power lines systems usually require much larger coupling/decoupling networks which substantially increase system size. EM test environments with ground planes with connections to earth are required to safely use transient generators.



    Common Combination Wave/Surge Tests

    • IEC/EN 61000-4-5 specifies two Combination Wave pulses: Open Circuit Voltage Short Circuit Current
    • A common combination wave test is the 1.2/50 & 8/20
    • Another common wave test is the 10/700 & 5/320, or otherwise known as telecom wave
    • The four standard test levels , excluded of EUT: 0.5, 1, 2, 4 kV (0.25, 0.5, 1, 2 kA)

     

  • 6 kV Surge Generators

     

    BCI Testing & Equipment           Automotive EMI/EMC Testing            EFT/Burst Generators           LISN's

     

    Combination Wave/Surge generators are required to meet IEC/EN 61000-4-5, ANSI (IEEE) 62.41 and other conducted immunity standards requiring a surge EMC test. The EMC Shop stocks all types of Combination Wave/Surge generators for compliance and pre-compliance testing. Rent or buy Combination/Surge generators for individual tests or multifunction generators to complete an assortment of tests in a compact solution. Most systems can be easily upgraded to include additional tests as required.

    Get Application Support, Pricing, Lead Time and More: Contact Form



    Combination Wave/Surge generators are typically benchtop, but heavy equipment. When doing testing on three phase power lines systems usually require much larger coupling/decoupling networks which substantially increase system size. EM test environments with ground planes with connections to earth are required to safely use transient generators.



    Common Combination Wave/Surge Tests

    • IEC/EN 61000-4-5 specifies two Combination Wave pulses: Open Circuit Voltage Short Circuit Current
    • A common combination wave test is the 1.2/50 & 8/20
    • Another common wave test is the 10/700 & 5/320, or otherwise known as telecom wave
    • The four standard test levels , excluded of EUT: 0.5, 1, 2, 4 kV (0.25, 0.5, 1, 2 kA)

     

  • 10 kV Surge Generators

     

    BCI Testing & Equipment           Automotive EMI/EMC Testing            EFT/Burst Generators           LISN's

     

    Combination Wave/Surge generators are required to meet IEC/EN 61000-4-5, ANSI (IEEE) 62.41 and other conducted immunity standards requiring a surge EMC test. The EMC Shop stocks all types of Combination Wave/Surge generators for compliance and pre-compliance testing. Rent or buy Combination/Surge generators for individual tests or multifunction generators to complete an assortment of tests in a compact solution. Most systems can be easily upgraded to include additional tests as required.

    Get Application Support, Pricing, Lead Time and More: Contact Form



    Combination Wave/Surge generators are typically benchtop, but heavy equipment. When doing testing on three phase power lines systems usually require much larger coupling/decoupling networks which substantially increase system size. EM test environments with ground planes with connections to earth are required to safely use transient generators.



    Common Combination Wave/Surge Tests

    • IEC/EN 61000-4-5 specifies two Combination Wave pulses: Open Circuit Voltage Short Circuit Current
    • A common combination wave test is the 1.2/50 & 8/20
    • Another common wave test is the 10/700 & 5/320, or otherwise known as telecom wave
    • The four standard test levels , excluded of EUT: 0.5, 1, 2, 4 kV (0.25, 0.5, 1, 2 kA)

     

  • 15 kV Surge Generators

     

    BCI Testing & Equipment           Automotive EMI/EMC Testing            EFT/Burst Generators           LISN's

     

    Combination Wave/Surge generators are required to meet IEC/EN 61000-4-5, ANSI (IEEE) 62.41 and other conducted immunity standards requiring a surge EMC test. The EMC Shop stocks all types of Combination Wave/Surge generators for compliance and pre-compliance testing. Rent or buy Combination/Surge generators for individual tests or multifunction generators to complete an assortment of tests in a compact solution. Most systems can be easily upgraded to include additional tests as required.

    Get Application Support, Pricing, Lead Time and More: Contact Form



    Combination Wave/Surge generators are typically benchtop, but heavy equipment. When doing testing on three phase power lines systems usually require much larger coupling/decoupling networks which substantially increase system size. EM test environments with ground planes with connections to earth are required to safely use transient generators.



    Common Combination Wave/Surge Tests

    • IEC/EN 61000-4-5 specifies two Combination Wave pulses: Open Circuit Voltage Short Circuit Current
    • A common combination wave test is the 1.2/50 & 8/20
    • Another common wave test is the 10/700 & 5/320, or otherwise known as telecom wave
    • The four standard test levels , excluded of EUT: 0.5, 1, 2, 4 kV (0.25, 0.5, 1, 2 kA)

     

  • 30 kV Lightning Surge Simulators

    Combination Wave/Surge generators are required to meet IEC/EN 61000-4-5, ANSI (IEEE) 62.41 and other conducted immunity standards requiring a surge EMC test. The EMC Shop stocks all types of Combination Wave/Surge generators for compliance and pre-compliance testing. Rent or buy Combination/Surge generators for individual tests or multifunction generators to complete an assortment of tests in a compact solution. Most systems can be easily upgraded to include additional tests as required.

    Get Application Support, Pricing, Lead Time and More: Contact Form



    Combination Wave/Surge generators are typically benchtop, but heavy equipment. When doing testing on three phase power lines systems usually require much larger coupling/decoupling networks which substantially increase system size. EM test environments with ground planes with connections to earth are required to safely use transient generators.



    Common Combination Wave/Surge Tests

    • IEC/EN 61000-4-5 specifies two Combination Wave pulses: Open Circuit Voltage Short Circuit Current
    • A common combination wave test is the 1.2/50 & 8/20
    • Another common wave test is the 10/700 & 5/320, or otherwise known as telecom wave
    • The four standard test levels , excluded of EUT: 0.5, 1, 2, 4 kV (0.25, 0.5, 1, 2 kA)

     

per page
Showing 37 - 48 of 51 items
    • Meet UL 1449, ANSI C62.41, IEC 61000-4-5, EN & IEC 60255-5
    • Cost effective CDN's for unshielded symmetric and asymmetric communication lines
    • Built in Single Phase CDN
    • 0.3kV – 6.0kV
    • 5.7" Color Touch Screen
    • Surge Voltage and Current Monitoring
    • Remote Control Functionality via LAN Ethernet
    In Stock
    Request Quote/More Info
  • Quick view
    $1,475.00 Monthly
    • Most Economical Surge Solution on the Market
    • Surge Simulation Pulse per IEC/EN 61000-4-5 & UL 1449 (pre-programmed)
    • Built-in Coupling Network for Single Phase DUT
    • 5.7" Color Touch Screen
    • Surge Failure Detection
    • Remote Control Functionality via LAN Ethernet
    $1,475.00
    In Stock
    Request Quote/More Info
    • Surge Simulation Pulse per IEC/EN 61000-4-5 & UL 1449
    • Coupling/Decoupling Networks for Single and Thrre Phase DUT
    • 5.7" Color Touch Screen
    • Surge Failure Detection
    • Remote Control Functionality via LAN Ethernet
    In Stock
    Request Quote/More Info
    • IEC/EN 61000-4-5 & ANSI C62.45: SurgeModule up to 5kV
    • IEC/EN 61000-4-4: Burst Module up to 5.5kV
    • IEC/EN 61000-4-11: Dips Interrupts and Variations
    • Built in Single phase 300 Volt/16 Amp coupler
    • Manual operation from front panel
    • USB and GPIB-Bus for remote control
    • Monitor outputs for peak voltage and peak current
    • Fail inputs
    • External variac control 0-10Vdc
    6 - 8 Weeks
    Request Quote/More Info
    • EUT DC load capacity: DC 1500V 100A
    • EUT AC load capacity: AC 700V 100A three-phase five wire
    • 0.2kV-6kV Voltage Range
    • 0.1kA-3kA Current Range
    • Semi-conductor switch technology,EUT power automatic switching over
    • EUT voltage and current detection
    • Overvoltage, over current and overheating protection
    In Stock
    Request Quote/More Info
    • 20kV±10% Output peak voltage
    • color touch screen 7 inch LCD 
    • PLC controlled automatic control system 
    • Changeable main circuit to generate multiple waveforms 
    • One-click test with programmable function 
    • RS 232 interface for remote control 
    • Built-in ground installation and safety interlock
    In Stock
    Request Quote/More Info
    • Surge Module Puse 10/700us per IEC/EN 61000-4-5 & ITU ETSI
    • Cost effective CDN's for unshielded symmetric and asymmetric communication lines
    • 5.7" Color Touch Screen
    • Surge Failure Detection
    • Remote Control Functionality via LAN Ethernet
    In Stock
    Request Quote/More Info
    • 10" Color Touch Screen
    • Intelligent HV Mains Charging Mode
    • Automatic Control System, Failure Analysis and more
    • Built in Single or Three Phase CDN
    • 300V - 10kV (±10%) Output Voltage
    • Configure with 10/700 Telecom Wave if Required
    In Stock
    Request Quote/More Info
  • In Stock
    Request Quote/More Info
    • Price are Per Month
    • PerformPrecompliance To:
    • Monitor surge voltage and current at the output terminals 
    • Creates custom test protocols
    • Built in 1 Phase Coupler, 50-277 VAC, 16 Amps (100 VDC,10A) Maximum
    Typically In Stock
    Request Quote/More Info
    • See the EMCPro Plus here
    • Perform Precompliance To:
      • IEC 61000-4-5 Surge Testing (6kV)
      • EFT testing to IEC 61000-4-4 limit (4kV)
      • PQF Dips and Interrupts to IEC 61000-4-11
    • Monitor surge voltage and current at the output terminals 
    • Creates custom test protocols
    Typically In Stock
    Request Quote/More Info
    • Combination wave
      • Voltage: 1,2/50us
      • Current: 8/20us
    • Impulse voltage: 200V - 4.2kV
    • Impulse current: 100A - 2.1kA
    • Maximum impulse repetition rate 12 per minute
    • Positive, negative and user definable alternating polarity
    • Integrated CDN for 16A at 264Vac and 110Vdc
    • Impulse voltage, current and EUT current measurement
    • Test parameter ramp functions
    • Phase angle synchronization
    Typically In Stock
    Request Quote/More Info
Showing 37 - 48 of 51 items