Viewed products
Meet UL 1449, ANSI C62.41, IEC...
Use with probes 8700i and 8705C 10...
New
Warning: Last items in stock!
Availability date:
Voltage Rating | AC 110V/220V , ±10%, |
Frequency Range | 50/60Hz±5% |
Standards Met | UL 1449, ANSI C62.41, IEC 61000-4-5, EN & IEC 60255-5, GB/T 17626.5 |
RF Connector | BNC, 5VTTL |
Mains & EUT Connections | 4mm banana plug |
Pulse voltage (open circuit) | 0.3kV–6.0kV ±10% |
Impedance | 2 phm, Optional 12 ohm and 500 ohm |
Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse) Pulse conforms to IEC/EN 61000-4-5 | |
Parameter | Value |
Pulse current (short circuit) | 0.15 kA–3.0kA ±10% (2ohm) |
Coupling | Optional for external SPN series CDN's |
Pulse repetition | 1-999 |
Polarity | Positive, Negative and Alternating |
Test duration | 6s-99s |
Telecom Surge As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations | |
Parameter | Value |
Test Voltage | 0.2kV–6.0kV,±10% |
Polarity | Positive, Negative or Alternate |
Counter | 1-999 |
Front Time | Voltage: 10us±20%, time to half value: 700us±20%; |
Pulse Duration | 11s-99s (shortest depends on test voltage) |
Output Current | Front time: 5us±20%, time to half value: 320us±20% |
Transfer Impedance | 15ohm, 40ohm (automatic switch) |
Dimensions | 19 inch/6u |
Weight | Approx 15 kg (33 lbs) |
The 3ctest CWS 600CT combination wave and telecom surge simulator provides 1.2/50us, 8/20us, 10/700us and 5/320us waveforms per UL 1449, ANSI C62.41, IEC 61000-4-5, EN & IEC 60255-5, GB/T 17626.5 and other test standards. CDN's are available for unshielded symmetric or assymetric communication lines. Software can be used to control the surge simulator remotely, make measurements and generate test reports.
The CWS 600CT has a modern color touch screen interface making it easy to set up and run test sequences. Software is available to generate reports and control the system remotely.