Viewed products
32 Amperes Current Rating 9 kHz – 30...
150 MHz - 230 MHz Fequency Range...
New
Warning: Last items in stock!
Availability date:
Frequency Range | 9 kHz – 30 MHz |
Standards Met | ANSI C63.4, CISPR 16-1-2 |
RF Connector | RF Measurement Port 50Ω – N-Type (female) |
Inductors | 50 µH |
Mains & EUT Connections | Remote Interface Power Input Port 5.5/2.5 mm Power Jack |
Application/Test Type | Power Line Conducted Emissions Tests |
Insertion loss | less than 0.7 dB |
Isolation | more than 40 dB |
Current rating | 32 Amperes |
Dimensions | 19.3” x 13.9” x 2.3″ |
Weight | 27.5 lbs. |
The Com-Power LI-3P-232 LISN provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products. The LISN will perform each of the following functions during the measurement:
The LI-3P-232 LISN uses air-core inductors to prevent saturation and permeability variation. The mounting plates are left unpainted in order to facilitate connection to earth ground in their installation, which is essential due to high leakage currents. The side panels for the LISN are louvered for cooling purposes.
Standards | Met ANSI C63.4, CISPR 16-1-2 |
RF Connector | RF Measurement Port 50Ω – N-Type (female) |
AC Voltage (maximum) | 500 Voltsrms (line to line), 288 Voltsrms (line to ground) |
DC Voltage (maximum) | 705 Volts DC |