CISPR 16 LISN's

Quick Links

Information

Viewed products

Com-Power LI-220C 9 kHz - 30 MHz LISN View larger

Com-Power LI-220C 9 kHz - 30 MHz LISN for CISPR 16-1-2/ANSI C63.4

Rental

  • 9 kHz to 30 MHz Frequency Range
  • Fully Compliant with CISPR 16-1-2/ANSI C63.4
  • Dual-Conductor Network with Universal
  • Power Receptacle to accept any EUT Plug
  • 20 Amps Current Handling Capability

More details

Typically In Stock

$400.00 + Shipping

Request Quote/More Info

Specifications

Voltage Rating270 VAC (Line to Ground), 380 VDC
Frequency Range 9 KHz - 30 MHz
RF Connector50Ω N-type (female)
Standards MetCISPR 16-1-2 / ANSI C63.4
Inductors 250 & 50 microhenry (air-core)
Mains & EUT ConnectionsSuperior Electric SUPERCON® shrouded sockets
Current Rating20 Amperes AC, 14 Amperes DC
Application/Test TypePower line conducted emissions tests
Insertion Loss6 dB to 1 dB
Isolation20 dB to 40 dB
Dimensions16.75 x 15.5 x 7.5 inches / 42.5 x 39.3 x 19 cm
Weight20.5 lbs / 9.3 kg

Test Equipment Description

The LI-220C is a 30 MHz, 20 A LISN from Com-Power. A line impedance stabilization network (LISN) device is something engineers use to test radiofrequency (RF) emission and susceptibility. During an electronic equipment test, engineers place the LISN device between an alternating current or direct current power source and the equipment under test.

The LI-220C Line Impedance Stabilization Network (LISN) provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products. The LI-220C is compliant with both CISPR 16-1-2 and ANSI C63.4. The LISN provides defined stable impedance and isolates the EUT from power source influences, thereby providing accurate and repeatable results. The LI-220C includes one pair of single-conductor networks, housed together, to be installed in series with each current-carrying conductor in a single- phase, dual-phase or DC power system. A second LI-220C pair can be used to accommodate 3-phase power systems (Wye or Delta configurations).

This LISN uses air-core inductors to prevent saturation and permeability variation. The mounting plate of the LI-220C is left unpainted in order to facilitate connection to earth ground in its installation, which is essential due to high leakage current. Use of a Transient Limiter for impedance matching, reduction of out-of-band emissions and transient protection for your measurement instrument is highly recommended and available from Com- Power. All Com-Power LISNs are individually calibrated in compliance with the relevant requirements of CISPR 16-1-2 and ANSI C63.4. Impedance, Phase, Isolation, and Insertion Loss data is supplied with each unit, along with the calibration certificate.

The LI-220C Line Impedance Stabilization Network (LISN) is in full compliance with both CISPR 16-1-2 and ANSI C63.4. It provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products. The LI220C performs each of the following functions during the measurement:

  • Provides a defined, stable impedance across the measurement frequency range
  • Isolates the EUT and measurement circuit from the power source, thereby minimizing its influence on the measurements
  • Couples the disturbance voltages to the coaxial measurement port for connection to the measuring instrument.

This LISN uses air-core inductors to prevent saturation and permeability variation. The mounting plate of the LI-220C is left unpainted in order to facilitate connection to earth ground in its installation, which is essential due to high leakage current.

Versatility

The LI-220C is a dual-conductor network capable of handling currents up to 20 Amps(AC) per line. The EUT power port is fitted with a universal, multi-configuration receptacle, which accommodates almost any EUT plug without the need for adapters. The power input port is fitted with a standard IEC C20 receptacle.

Transient Protection

Com-Power Transient Limiters are a recommended accessory in order to protect the RF input of your measuring instrument from potentially damaging, instantaneous voltage transients. The transient limiter also reduces the possibility of overload by incorporating two 5 dB attenuation/impedance matching pads, in addition to its low-pass and high-pass filter sections which further attenuate any out-of-band emissions.

Calibration

All Com-Power LISNs are individually calibrated in compliance with the relevant requirements of CISPR 16-1-2 and ANSI C63.4. Impedance, Phase, Isolation, and Insertion Loss data is supplied with each unit, along with the certificate of calibration. Recognized ISO 17025 accredited calibration is also available upon request.

Typical Impedance Data

Typical Impedance Data

Typical Phase Data

Typical Phase Data

Typical Insertion Loss

Typical Insertion Loss

Typical Isolation Data

Typical Isolation Data

Associated EMC Test Equipment