Frequency Range | 150 kHz to 1000 MHz |
Standards Met | IEC/EN 61000-4-6 CISPR 24 EN 61000-6-1 EN 61000-6-2 IEC 60533 IEC 60601-1-2 IEC 61326 |
Application/Test Type | decoupling network (ferrite tube) for immunity test according to IEC / EN 61000-4-6 |
Max. Cable Diameter | 35 mm |
Dimensions | 670 mm x 70 mm x 80 mm |
Weight | approx. 8 kg |
The FT 801 is recommended as an additional decoupling network (ferrite tube) for immunity test according to IEC / EN 61000-4-6 when using the clamp injection method. It shall be inserted on all the cables between EUT and AE except the cable under test. The FT 801 prevents, that the test signal applied to the EUT affects other devices, equipment or systems, which are not under test and improves the reproducibility of the test results.