EM Test / Luthi EM 101 EM Injection Clamp for IEC/EN 61000-4-6

New

  • As specified in IEC 61000-4-6 (incl. edition 4 and EN 61000-4-6:2014)
  • Very Efficient Coupling
  • Can be used on almost any cable
  • Ruggedly designed
  • Improved locking system

More details

Request Quote/More Info

Specifications

Frequency Range10 kHz to 1000 MHz
Standards MetIEC/EN 61000-4-6; CISPR 24; EN 61000-6-1; EN 61000-6-2; IEC 60533; IEC 60601-1-2; IEC 61326
Application/Test TypeInjects the disturbance signal through a combination of inductive and capacitive coupling
Impedance50 Ohms
Maximum Continuous Power0.01 to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 3 min; 230 to 1000 MHz: 50 W for 3 min
ConnectorN-type female
Clamp factor (CF)Max (0.15 to 400 MHz): 4 dB (50 Ω system) and 13.5 dB (150 Ω system)
Max. Cable Diameter20 mm
Dimensions647 mm x 130 mm x 105 mm
Weightapprox. 7 kg

Test Equipment Description

Rent, buy or lease the EM Test / Luthi EM101 EM Injection Clamp for IEC/EN 61000-4-6. The EMC Shop stocks turnkey systems to test RF conducted immunity.

EM Injection Clamp For IEC / EN 61000-4-6

IEC 61000-4-6 (EN 61000-4-6) defines three basic types of transducer used for the injection of test signals into the equipment under test (EUT). The basic requirement is to inject a known level of RF signal onto the cable of the EUT at each test frequency and to determine whether the EUT continues to function correctly. In order to do this, it is necessary to decouple the auxiliary equipment (AE) from the test signal. If this is not achieved it is difficult to know whether any fault is due to a failure of the EUT or the AE. Whilst the coupling/decoupling network (CDN) is one of the best ways to achieve this test and indeed it is mandatory to use them under some circumstances, it is not always possible to use a CDN.

The normative Annex A of IEC/EN 61000-4-6 gives additional information regarding the clamp injection. The EM Test / Luthi EM101 EM Injection Clamp for IEC/EN 61000-4-6 is similar to the described EM clamp in the standard and injects the disturbance signal through a combination of inductive and capacitive coupling. The use of a ferrite cores along the length of the clamp also improves the common mode impedance of the test set-up and the reproducibility of the test. Optionally offered is the calibration kit CAL 801A which allows test level setting and correction factor measurement.

Associated EMC Test Equipment

9 other products in the same category: