EUT Transient Monitors

Quick Links

Information

Viewed products

Langer A200-2 2 Channel Optical Probe Set for EUT Monitoring

New

  • Optical Fibre Probe 2-Channel, 500 kHz
  • Consists of two sensors
  • Allow for potential free transmission of analog signals under EFT/ESD/RF interference
  • Signals are displayed on an oscilloscope
  • Disturbed signals can be easily detected
  • Suitable for monitoring signals or devices
  • For EMC optimizing of hard- and software

More details

Request Quote/More Info

PDF Downloads

User Manual

A100 / A200 / A300 Optical Fibre Probe

PDF Downloads (1M)

Test Equipment Description

The A200-2 Set consists of two sensors which allow for potential free transmission of analog signals under EFT/ESD/RF interference. The signals are displayed on an oscilloscope. Disturbed signals can be easily detected. In the device under test the sensor transforms the measured logic signals into optical signals. The optical signals are transmitted via a fibre optical cable to the optical receiver which transforms them into electrical signals. These can be seen with an oscilloscope or can be used for controlling other devices. The system is suitable for monitoring signals or devices under test in an anechoic chamber or for EMC optimizing of hard- and software.

Scope of delivery

2x AE 200, Optical Receiver
2x AS 200, Optical Sensor (50 / 10) V DC
2x LWL Ø 2.2 mm 6 m, Optical Fibre, Single 6 m
1x NT FRI EU, Power Supply Unit
1x A200-2 acc, Accessories
1x A200-2 case, System Case
1x Analog m, User Manual

Additional sensors are available on request and can be added to the set.

Technical Parameters
BandwidthDC ... 500 kHz
Sampling rate3 Msps
Resolution12 Bit
AE 200 Optical Receiver
BandwidthDC ... 500 kHz
Voltage range - output0 V ... 10 V
Optical input: Optical fiberØ 2.2 mm
Supply voltage12 V ... 16 V
Current input≈ 100 mA
AS 100 Optical Sensor
BandwidthDC ... 500 kHz
Measuring range0 V ... 50 V / 0 V ... 10 V DC (switchable)
Input resistance100 kΩ
Radiated immunity> 100 V/m
Supply voltage3 V ... 16 V
Current input≈ 30 mA
Optical fibre length1 m ... 20 m

Usage

Measurement under interference conditions

Measurement of analogue electrical signals under extreme electromagnetic stress such as:

  • Coupling of radiated or conducted RF emissions
  • Fast transients burst/ESD
  • High potential (high voltage)

EMC tests as the main field of application:

  • Radiated RF emissions EN 61000-4-3: 80 MHz - 1 GHz, 80% AM (1 kHz), anechoic chambers TEM cells stripline,
  • Conducted RF emissions EN 61000-4-6: 40 Veff, 150 kHz - 230 MHz, 80% AM (1 kHz)
  • Burst EN 61000-4-4
  • ESD EN 61000-4-2

Measured signals:

  • Supply voltages (switching controllers, linear controllers),
  • Reference voltages,
  • Digital signals (optical couplers, optical receivers),
  • Analogue signals (operational amplifiers, ADC, DAC).

Specific measurement technology:

To measure analogue signals under extreme interference conditions, measurement technology is needed that

  • itself is not affected by disturbance fields and thus does not simulate any disturbance in the equipment under test (EUT).
  • can be connected to the EUT in a decoupled way, i.e. connecting the probe head does not result in the development of additional disturbance current paths through which disturbances can penetrate or be discharged.

The A100 / A200 / A300 optical fibre measurement systems meet these demands.

Figure 1 The oscillogram shows a constant useful signal with a demodulated 1 kHz component.Figure 2 The demodulated 1 kHz disturbance signal, superimposed on the useful signal, shows a large harmonic component.
Figure 3 The demodulated 1 kHz disturbance signal is limited by the lower rail.Figure 4 Useful signal without interference
Figure 5 Useful signal with 1 kHz disturbance signalFigure 6 Useful signal with 1 kHz disturbance signal limited by the upper rail

Safety instructions

When using a product from Langer EMV-Technik GmbH, please observe the following safety instructions to protect yourself from electric shock or the risk of injuries.

Read and follow the instructions in the user manual and keep it in a safe place for later reference. The device may only be used by personnel who are qualified in the field of EMC and who are fit to work with and possibly be influenced by disturbance voltages and (electric and magnetic) burst fields.

  • Read the operating and safety instructions for all devices used in the set-up.
  • Never use any damaged or defective devices.
  • Only connect and disconnect an AS XXX sensor when it is not subjected to any interference.
  • Carry out a visual check before using a measurement set-up with a Langer EMV-Technik GmbH product. Replace any damaged connecting cables before using the product.
  • Never leave a product from Langer EMV-Technik GmbH unattended whilst it is in operation.
  • The Langer EMV-Technik GmbH product may only be used for its intended purpose. Any other use is forbidden.
  • People with a pacemaker are not allowed to work with this device.
  • The test set-up should always be operated via a filtered power supply.

Attention! Functional near fields and interference emissions may occur when the probe is operated. The user is responsible for taking appropriate precautions to prevent any interference with the correct function of products outside the operational EMC environment (in particular through interference emissions).
This can be achieved by:

  • observing an appropriate safety distance
  • using of shielded or shielding rooms

The disturbances that are injected into the modules can destroy the device under test (latch-up) if their intensity is too high. Protect the device under test by:

  • increasing the disturbance gradually and stopping when a functional fault occurs
  • interrupting the power supply to the device under test in the event of a latch-up.

Attention! Make sure that internal functional faults are visible from outside. The device under test may be destroyed due to an increase in the injection intensity if the faults are not visible from outside.

Take the following precautions if necessary:

  • monitor the representative signals in the device under test
  • use a special test software
  • monitor visible reaction of the device under test to inputs (reaction test of the device under test).

We cannot assume any liability for the destruction of devices under test!

Warranty

Langer EMV-Technik GmbH will remedy any fault due to defective material or defective manufacture, either by repair or by delivery of spare parts, during the statutory warranty period.

This warranty is only granted on condition that:

  • the information and instructions in the user manual have been followed.

The warranty will be forfeited if:

  • an unauthorized repair is performed on the product,
  • the product is modified,
  • the product is not used for its intended purpose.

Associated EMC Test Equipment

7 other products in the same category: