Ring Wave Immunity Generators

Quick Links

Information

Viewed products

Rent Keytek ECAT Ring Wave Simulator for ANSI/IEEE C62.4 and UL 864 View larger

Rent Keytek ECAT Ring Wave Simulator for ANSI/IEEE C62.4 and UL 864

Used

  • Rentals Ship Immediately
  • System Configuration:
    • E103 Controller (fiber-interface for remote control)
    • E503 Ring Wave Simulator to 6.6kV (ANSI/IEEE C62.41 Cat. A and B and UL 864)
    • E4551A Single Phase Surge/EFT Coupler 250V rms (typ. 15 Amps)
    • Optional Modules Available (Call to Configure):
      • E411 EFT Simulator to 4.4 kV
      • E421 EFT Simulator to 8 kV
      • E501B Surge Simulator to 6.6 kV

More details

In Stock

Request Quote/More Info

Specifications

Standards MetANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864
Ringwave 0.5 μs/100 kHz
Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
ParameterValue
Pulse voltage (open circuit)200V - 6.6kV ± 10%
Pulse current (short circuit)Selectable at 200A max. or 500A max., when the open-circuit voltage is set to 6.0kV.
Pulse repetition1 shot/9 seconds

Test Equipment Description

How to Rent the ECAT Ringwave System:

  • Click "Add to Cart" above
  • Shipping Section - Select "Use My Account" - we ship this system freight to keep it upright. Indicate in the Notes section if you'd like us to facilitate shipment or if your logistics team will do so.
  • Checkout Accordingly
  • An EMC Shop representative will contact you with shipping estimates or logistics details.

About the Keytek ECAT System:

The Thermo Fisher Keytek ECAT Simulator systems are a sesoned favorite being used for electromagnetic Surge and EFT testing for more than 2 decades. The controller has an easy-to-use Windows based application software for quick implementation of test routines and standards, with automoatic report generation. A multi-level system interlock architecture provides maximum safety to keep first time users safe.

This rental ECAT system is suitable for users looking to evaluate DUT in a precompliance environment for passing Surge and Burst (Electrical Fast Transient) immunity test standards such as IEC 61000-4-4, IEC 61000-4-5 and ANSI C62.41. The single phase, 15 amp coupling network is suitable for most commercial electronics and lower powered electronics.

ECAT Ringwave Simulator Configuration:

  • E103 Controller (fiber-interface for remote control)
  • E503 Ring Wave Simulator to 6.6kV (ANSI/IEEE C62.41 Cat. A and B and UL 864)
  • E4551A Single Phase Surge/EFT Coupler 250V rms (typ. 15 Amps)
  • Optional Modules Available (Call to Configure)
    • E411 EFT/Noise Burst Simulator to 4.4 kV (IEC 61000-4-4)
    • E421 EFT/Noise Burst Simulator to 8 kV (IEC 61000-4-4)
    • E501B Surge Simulator to 6.6 kV (IEC 61000-4-5, ANSI C62.41 Cat. B and UL 1449 at 3kA)
  • Input voltage: 100V to 240VAC
  • Input Current: 3.5A at 100 V; 1.5A at 240 V
  • User Manual
  • NIST Calibration Certificate

Associated EMC Test Equipment