RF Power Line CDN's

The EMC Shop stocks power line coupling decoupling networks for RF conducted immunity testing. The distubance signals are coupled to each conductor in the supply lines according to EN IEC 61000-4-6 standard. The standard M series CDNs have a current rating of 25 Amps. CDNs are available for power supplies from 1 to 5 conductors.

Get Application Support, Pricing, Lead Time and More: Contact Form

RF Power Line CDN's

  • M1 for one line
  • M2 for two lines
  • M2/3 switchable for two or three lines
  • M3 for three lines
  • M4 for lines and
  • M5 for five lines "-10 types" for frequency range 10 kHz to 80 MHz
  • "-3L and -3LN types" for connections without PE "-750V, -760V
  • -1000V types" for higher EUT voltages

RF Power Line CDN's There are 34 products.

Subcategories

  • 1 Line CDN

    1-line CDN's for 1 PE line power compliance testing in accordance to IEC 61000-4-6 and other standards. The M1 power line CDN is used to couple common mode CW and modulated signals onto single power line systems. The M1 can be ideal for automotive systems using the chassis as the DC return

    The EMC Shop carries an assortment of M-type 1 line coupling/decoupling networks with different current ratings and connector types.

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • 2 Line CDN

    2-line CDN's for L+N, DC +, DC- power compliance testing in accordance to IEC 61000-4-6 and other standards.

    The M2 is commonly used for 2 wire power conductor cables.

    The EMC Shop carries an assortment of M-type 2 line coupling/decoupling networks with different current ratings and connector types.

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • 3 Line CDN

    3-line CDN's for L+N+PE, 2L+PE, or 3L power compliance testing in accordance to IEC 61000-4-6 and other standards.

    M3 is used for two line single phase cables.

    The EMC Shop carries an assortment of M-type 3 line coupling/decoupling networks with different current ratings and connector types.

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • 4 Line CDN

    4-line CDN's for 2L+N+PE, 3L+PE, 3L+N, 3L+N+PE power compliance testing in accordance to IEC 61000-4-6 and other standards.

    The M4 is used on three phase power mains with P.E.

    The EMC Shop carries an assortment of M-type 4 line coupling/decoupling networks with different current ratings and connector types.

    Get Application Support, Pricing, Lead Time and More: Contact Form

  • 5 Line CDN

    5-line CDN's for 3L+N+PE power compliance testing in accordance to IEC 61000-4-6 and other standards.

    M5 is used on three phase systems with neutral and protected earth ground conductors.

    The EMC Shop carries an assortment of M-type 5 line coupling/decoupling networks with different current ratings and connector types.

    Get Application Support, Pricing, Lead Time and More: Contact Form

per page
Showing 13 - 24 of 34 items
    • 150 kHz - 230 MHz
    • 4 mm Safety Banana Sockets
    • 16 A Max. Current Rating
    • 250 VAC 400 VDC Input Voltage EUT
    In Stock
    Request Quote/More Info
    • 150 kHz - 230 MHz
    • For conducted common mode immunity testing according to IEC 61000-4-6
    • Compliant to IEC 61000-4-6 Annex D.2
    • Suitable for Immunity testing on unscreened A.C. and D.C. Power Supply lines (mains lines) with extended voltage rating up to 1000V.
    In Stock
    Request Quote/More Info
    • 150 kHz - 230 MHz
    • For conducted common mode immunity testing according to IEC 61000-4-6
    • Compliant to IEC 61000-4-6 Annex D.2
    • Suitable for Immunity testing on unscreened A.C. and D.C. Power Supply lines (mains lines) with extended voltage rating up to 1000V.
    In Stock
    Request Quote/More Info
    • 150 kHz - 230 MHz
    • For conducted common mode immunity testing according to IEC 61000-4-6
    • Compliant to IEC 61000-4-6 Annex D.2
    • Suitable for Immunity testing on unscreened A.C. and D.C. Power Supply lines (mains lines with extended voltage rating up to 1000V)
    In Stock
    Request Quote/More Info
    • 150 kHz - 230 MHz
    • For conducted common mode immunity testing according to IEC 61000-4-6
    • Compliant to IEC 61000-4-6 Annex D.2
    • Suitable for Immunity testing on unscreened A.C. and D.C. Power Supply lines (mains)
    In Stock
    Request Quote/More Info
    • 10 kHz – 230 MHz Frequency Range
    • 32 Current Rating (AE-EUT) (A)
    • 3 x L, PE Terminal assignment
    In Stock
    Request Quote/More Info
    • Coupling/Decoupling Network (CDN) CDN M Type
    • Designed for IEC/EN 61000-4-6 Conducted RF Immunity Testing
    • CDN M016 switchable M2 or M3
    • Types with 4 mm banana sockets
    • Performance up to 230 MHz
    In Stock
    Request Quote/More Info
    • Coupling networks designed for IEC/EN 61000-4-6
    • M1 series for mains applications
    • 4 mm banana sockets
    • 150 kHz to 230 (300) MHz
    • 16 A, (25 A for 1 s PE line test), for CDN M132: 32 A Max Current
    • 1 Amp max no saturation
    In Stock
    Request Quote/More Info
    • For 4 AC supply lines (L1/L2/L3/PE or N)
    • AE: 4mm safety lab connectors
    • EUT: 4mm safety lab connectors
    • AC: max. 3 x 400 V/16 A
    • DC: max. 1,000 V/16 A
    • Frequency 150 kHz - 230 MHz
    Typical Lead Time 4 - 6 Weeks
    Request Quote/More Info
    • For 5 AC supply lines (L1/L2/L3/N/PE)
    • AE: 4mm safety lab connectors
    • EUT: 4mm safety lab connectors
    • AC: max. 3 x 750 Volts / 100 Amps
    • DC: max. 1,000 Volts /100 Amps
    • Frequency 150 kHz - 230 MHz (up to 80 MHz on higher power models)
    Typical Lead Time 4 - 6 Weeks
    Request Quote/More Info
    • For 2 or 3 AC/DC supply lines (switchable)
    • AE: IEC 60320/C14 connector
    • EUT: 4mm safety lab connectors
    • AC/DC: max. 240 V/32 A
    • Frequency 150 kHz - 230 MHz
    Typical Lead Time 4 - 6 Weeks
    Request Quote/More Info
    • AE: 4mm safety lab connector
    • EUT: 4mm safety lab connector
    • AC: max. 250 Volts, 16/32/50/75/100 Amps
    • DC: max. 1,000 Volts, 16/32/50/75/100 Amps
    • Frequency 150 kHz - 230 MHz (up to 80 MHz on higher power models)
    Typically In Stock
    Request Quote/More Info
Showing 13 - 24 of 34 items