Accuracy | ±1.0dB @ 10MHz1 0.8dB, 100kHz–1GHz3,4 1.4dB, 1GHz–6GHz3,4 |
Rise time | Typical Analog 300nS |
Operating Temperature | 10˚C to 40˚C (50˚F to 104˚F) @ 5% to 95% RH non-condensing |
Dimensions | 5.7 x 5.7 x 5.7 cm (2.25 x 2.25 x 2.25 in)2.92 cm (1.15 in) DIA spherical housing3.18 cm (1.25 in) sensor radome per axes |
Weight | 62.5 g (2.2 oz) |
Analog Response Time | 20 msec/up to 50 samples per second, at FI7000 USB and GPIB interfaces |
Isotropic Deviation | ± 0.5 dB @ 10 MHz± 0.5 dB, 5 kHz–30 MHz (typical) |
Linearity | ± 0.5 dB and ± 0.9 V/m |
Damage Level | 1000 V/m continuous field |
Power Requirements | Laser powered from FI7000 interface |
Temperature Stability | ± 0.5 dB over operating temperature range |
Operating Range | 1.5–300 V/m |
Fiber Optic Connectors | Two E2000 compact duplex connectors at 1 meter, includes fiber optic verification loop. |
Data Returned From Probe | X, Y, Z axes, and Composite |
Calibration Data | Accredited Calibration Report (A2LA) supplied with probe |
Is a smart, fast, extremely accurate electric field probe that contains an internal microprocessor to provide linearization, temperature compensation, control, and communication functions. Noise reduction and temperature compensation allow accurate measurements down to 1.5 V/m without zero adjustment. When rotated about its critical angle mount, the probe provides isotropic response of ±0.5 dB over its specified frequency range.
The FL7030 is laser powered to allow for continuous operation without battery recharging or replacement.
Correction factors are provided with the probe. These factors can be loaded into the Model FM7004 Field Monitor (sold separately) to automatically correct the probe readings at user-specified frequencies. When correction factors are applied, the true accuracy of the probe can be realized.
It communicates and is powered through glass fiber optic cables, up to 100 meters long, to the FI7000 interface. X, Y, Z, and isotropic readings can be returned through an FI7000 in 20 msec.
The FL7030 extends the range of AR laser powered E–field probes down to 5 kHz. It offers an extended post–detection response-smoothing time constant to provide more consistent readings for carrier frequencies down to 5 kHz.
FL7030 Typical Uncalibrated Frequency Response | FL7030 Typical Calibrated Frequency Response (with correction factors applied) |