Electric E-Field Probes up to 40 GHz

Quick Links

Information

Viewed products

ETS-Lindgren HI-6153 Electric Field Probe, 10 MHz - 40 GHz

New

  • Laser Powered for Unlimited Test Time 
  • Frequency Range: 10 MHz to 40 GHz 
  • Dynamic Range: 2.0 to 800 V/m (Single Range) 
  • Provides Individual and Summed Axis Values 
  • A2LA Accredited Calibration Report
  • Suitable for IEC 61000-4-3, GMW3097, SAE J113, MIL-STD-461 RS103 and more.

More details

Typically In Stock

Request Quote/More Info

Test Equipment Description

The ETS-Lindgren HI-6153 Laser-powered Electric Field Probes provide broadband EMF frequency coverage and wide dynamic range that satisfies the demands of most test requirements. To take advantage of this capability, the HI-6153 RF field probe was designed to be single range reading so data can be read continuously over the entire dynamic range. Data values for each axis (X,Y,Z) can be read individually, or summed.

​Fiber optic signal and power lines link the ETS HI-6153 probe to either the model HI-6100 Field Monitor, or as a direct connect to a PC USB port with the HI-6113 Laser Data Interface and ProbeView Laser Software.

The ETS HI-6100 provides manual functions and programmed control via IEEE-488 and RS-232 Serial Data Interfaces. Readings from up to four probes can be displayed simultaneously.

The EMCenter™ Modular RF Platform along with the EMSense™ interface card can be used with the HI-6000 series field probes as a field monitor in addition to its capability as a system level platform.

The ETS-Lindgre HI-6113 provides the laser power and communications for the HI-6153. A USB connection to the PC allows for quick and easy data collection, using ProbeView Laser software.

ETS-Lindgren HI-6153 Specifications:

Detection Isotropic: (X, Y, and Z Axis Readings)
Frequency Range: 10 MHz to 40 GHz
Frequency Response with Correction:

  • 10 MHz to 18 GHz ± 0.9 dB
  • 18 to 40 GHz ± 1.1 dB

Frequency Response (Typical): 

  • 10 to 100 MHz + 3.0, -4.0 dB
  • 100 MHz to 1 GHz +3.0, -0.50 dB
  • 1 to 18 GHz +4.0, -2.0 dB
  • 18 to 40 GHz +3.5, -4.5 dB

Dynamic Range: 2 to 800 V/m (Single Range)
Resolution:  0.01 V/m
Isotropic Deviation: ±1.0 dB < 18 GHz
Linearity: ±0.5 dB   
Sample Rate (Typical): 70 Samples per Second Maximum
Overload Withstand: >1500 V/m CW

Associated EMC Test Equipment