Frequency Range | 100 kHz to 6 GHz |
Standards Met | IEC/EN 61000-4-3 |
Application/Test Type | Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF rooms for radiated immunity testing. |
RF Field Probes E-Field | |
Parameter | Value |
Sensors | Three monopoles |
Measurement Mode | X-Y-Z and Composite |
Sampling Rate | 20 msec/up to 50 samples per second, USB and GPIB only |
Digital Filtering | N/A |
Battery | N/A |
Operation Time | Laser Powered - Seemless |
Recharging Time | N/A |
Flatness | Frequency correction OFF: ±1.0 dB @ 10 MHz Frequency correction ON: typically 0.8 dB, 100 kHz–1 GHz 1.4 dB, 1 GHz–6 GHz |
Dynamic Range | 0.5–800 V/m, 100 kHz–1 GHz; 0.5–600 V/m, 1 GHz–4 GHz; 0.7–800 V/m, 4 GHz–6 GHz (Single Range) |
Overload | 1,000 V/m CW 10,000 V/m Peak |
Internal Data Memory | None |
Communication | USB, IEEE-488 (GPIB), RS-232 (serial), Fiber-Optic Serial |
PC Software | Optional Software for setup, automation and monitoring available. |
Temperature Reading Resolution | None |
Resolution | 0.01 V/m |
Dimensions | 3.18 cm (1.25 in) |
Weight | 62.5 g (2.2 oz) |
The Amplifier Research (AR) FL7006 Electric Field Probe Kit, 100 kHz - 6 GHz is a laser powered, isotropic E-field diode probe. The FL7006 is a smart, fast, extremely accurate electric field probe that contains an internal microprocessor to provide linearization, temperature compensation, control, and communication functions. Noise reduction and temperature compensation allow accurate measurements down to 0.5 V/m without zero adjustment. Microprocessor based linearization technology provides a 64 dB dynamic range. When rotated about its ortho angle mount, the probe provides isotropic response of ±0.5 dB to over 2 GHz.
The FL7006 is laser powered to allow for continuous operation without recharging or battery replacement. This probe requires an FI7000 for power and communication. FM7004A is recommended for local monitoring and control.
Correction factors are provided with the probe. These factors can be loaded into the Model FM7004A Field Monitor (sold separately) to automatically correct the probe readings at user-specified frequencies. When correction factors are applied, the true accuracy of the probe can be realized.
The FL7006 communicates through glass fiber optic cables, up to 100 meters long, to the FI7000 interface. X, Y, Z, and isotropic readings can be returned through an FI7000 in 20 msec.
Note: FM7004A is recommended for local monitoring and control.