Viewed products
Electromagnetic relay protection if...
New
Warning: Last items in stock!
Availability date:
VVT/VMT/MFT series can be equipped with CCS simulator to produce voltage dip, interruption and variation to conduct automatic test. Test system can be communicated by Ethernet bus and controlled by EMSLab.
Accessories:
General Data | ||||||
Power supply | AC 110V/220V10%50/60Hz | |||||
Fuse | 6A | |||||
Max. power consumption | 50W | |||||
External control | 25 pin parallel line | |||||
Working indicator | LED display on front panel | |||||
Grounding connection | Flat grounding line | |||||
EUT power injection | 4mm banana line | |||||
Output mode | 1m coaxial cable | |||||
Dimension | 19’’/6U | |||||
Weight | Approx. 68kg(different models have different weight) | |||||
Temperature | 15–35° | |||||
Humidity | 45%–75% | |||||
Air pressure | 86kPa–106kPa | |||||
Power fail test as per IEC 61000-4-11 & IEC 61000-4-34 | ||||||
Technical parameters of single phase AC and DC voltage dip, short interruption and variation as per IEC/EN61000-4-11, GB/T17626.11 and IEC/EN61000-4-34, GB/T17626.34 | ||||||
EUT Max voltage | 250V AC | |||||
EUT max current | 16A continuous current; 500A impulse current; | |||||
Max. input mains | Single phase 220V±5%, 50/60Hz±5% | |||||
Voltage dip level | 0-100% | |||||
Voltage interruption level | 0% | |||||
Voltage variation level | 0-100% | |||||
Decrease time for voltage variation | 500ms-60000ms(50%-100%)or 1-5us(100 ohm load) 1000ms-60000ms(0%-100%)or 1-5us(100 ohm load) | |||||
Increase time for voltage variation | 500ms-60000ms(50%-100%) 1000ms-60000ms(0%-100%) | |||||
PFMF test | ||||||
Standards | IEC/EN 61000-4-8、GB/T 17626.8 | |||||
Magnetic field intensity | TCXS111 single-turn 1m*1m square magnetic coil: 1-100A/m continuous,100-400A/m(1-10s short time) TCXS113 three-turn 1m*1m square magnetic coil:1-300A/m continuous, 300-1200A/m (1~10s short time) | |||||
Waveform | 50Hz/60Hz sine wave | |||||
THID | <5% | |||||
Output current | 1A-500A | |||||
Waveform interval | 1-9999s | |||||
Test duration | 1-28800s | |||||
Trigger mode | Auto, manual, extern | |||||
Coil size | 1000*1000 mm or others | |||||
Coil shape | Rectangle or as the special requirements | |||||
Number of turns | single-turn or three-turn | |||||
Magnetic intensity | Can be programmable |