Viewed products
Test up to two balanced pair ITE's to...
Used
In Stock
Warning: Last items in stock!
Availability date:
Voltage Rating | 63 VAC RMS, 100 VDC |
Frequency Range | 150 kHz to 30 MHz |
RF Connector | 50Ω BNC female |
Mains & EUT Connections | D-sub 25 female |
Common Mode Impedance | 150 ± 20Ω |
Current Rating | 250 mA Maximum |
Application/Test Type | Measuring conducted emissions on two balanced pair telecom ITE’s. |
Decoupling of Common Mode Disturbance | 35 dB min. to 150 kHz; 55 dB min up to 30 MHz |
Voltage Division Factor | 9.5 dB ±1 dB |
Dimensions | 100 x 100 x 235 mm |
Weight | 1.0 kg (2.2 pounds) |
CISPR 22 defines ISN’s as specialized coupling decoupling devices used to measure the conducted asymmetric common mode radio interference voltages of an ITE. FCC CISPR 22 Impedance Stabilization Network (ISN) Part # FCC-TLISN-T4-02-09 meet the requirements of CISPR 22 for measuring conducted emissions on two balanced pair telecom ITE’s. Meet the requirements for Longitudinal Conversion Loss, common mode impedance, phase, decoupling isolation and voltage division factor.
For more CISPR product standards testing see our category page for ISN's listed below.