Power Fail Simulators

Quick Links

Information

Viewed products

3ctest PFS Single Phase Power Fail Simulator View larger

3ctest PFS Single Phase Power Fail Simulator

New

  • 5.7 inch color touch screen
  • Full compliant test as per IEC 61000-4-11, GB/T17626.11 
  • Built-in multi functional test module
  • Data acquisition of voltage and current
  • Programmable test procedures
  • Ethernet RJ45, PC remote control, test report documentation and print

Standard

  • IEC 61000-4-11
  • IEC 61000-4-29
  • GB/T 17626.11
  • GB/T 17626.29
  • EN 61000-4-11
  • EN 61000-4-29

More details

Request Quote/More Info

PDF Downloads

Test Equipment Description

3ctest PFS Single Phase Power Fail Simulator simulates voltage dip, interruption and variation which are caused by power grid and transformer devices due to malfunction or sudden large change of load. It is required to test this kind of phenomena to check whether electronic and electrical device can sustain safety operating condition. PFS 2216 SV is equipped with two semiconductor switch controlled independently. It can withstand impulse current and each switch has electronic protection function.

General Data
Display5.7 inch TFT touch screen
Power supply110V/220V, ±10%, 50/60Hz
Fuse6A
Max. Power consumption100W
Memory spaceInfinite (PC)
Communication modeEthernet LAN, RJ45
External controlD-sub 25p
External trigger inputBNC,5V TTL
CRO outputBNC,5V TTL
InputBNC,5V TTL
Synchronization45-65Hz, 20-500V between dotted terminal & undotted terminal
Warning LED0-220VAC 10A/0-48VDC 3A
Depending on external signal lamp
Safety circuitTest only can be started when it is closed
Failure testDisplay on LCD and interrupt the work at failure case
EUT voltage monitoring outputBNC, 100:1 coaxial output
EUT current monitoring outputBNC, 10A:1V coaxial output
Working indicatorLED, LCD front panel display
Grounding connectionFlat ground line
EUT power injection4mm banana line
Output modeStandard 1m coaxial cable
Size19 inch/6U/4U or 22U cabinet
Weight(different weight for different model)Eg. PFS 2210SVD / PFS 2210SD / PFS 2216SD  weight: 40Kg; PFS 1130D weight: 24Kg or 100kg (with the power supply)
Temperature15–35°C
Humidity45%–75%
Air pressure86kPa–106kPa
Power fail test as per IEC6100-4-11&IEC61000-4-29,GB/T17626.29 for single phase AC and DC including voltage dips, short interruption and variation
Power fail simulator
EUT max. VoltagePFS22xxSD, PFS22xxSVD series: 250V AC, 300V DC
PFS05xxD series: 55VDC
PFS11xxD series: 130VDC
PFS12xxD series: 140VDC
PFS22xxD series: 300VDC
EUT max. currentPFS2216SD, PFS2216SVD:
16A  AC/DC continuous current;  
20A continuous 5s;  
40Acontinuous 3s;

PFS2210SVD, PFS2210SVD: 
10A AC/DC continuous current;  
12A continuous 5s;  
25Acontinuous 3s;  

PFSxx05D: 6A  
PFSxx010D:12A
PFSxx20D: 22A
PFSxx25D: 28A
PFSxx30D: 33A
PFSxx50D:  55A
EUT power supplySingle phase  no more than 230V 50~60Hz±5%DC no more than 300VDC Offer DC control
EUT current and voltage measurementLCD display
BNC terminal: voltage 100:1, current 100A: 1V
Interrupt level0%
Dip level0%-100%(for accessories VVT/VMT series)
0%,40%,70%,80%(for accessories VVTxxxxSF series )
Repetition rate0.3-9999 cycle or 5ms-9999ms
Duration50ms-50000ms
Test time1s-9999s
Rise and fall time1-5us(100Ω load)
Voltage variation level0-100%
Time for decreasing voltage500ms-60000ms(50%-100%)or 1-5us(100 ohm load)
1000ms-60000ms(0%-100%)or 1-5us(100 ohm load)
Time for increasing voltage500ms-60000ms(50%-100%)
1000ms-60000ms(0%-100%)
Time for reduced voltage10ms-99999ms
DC voltage level0-120%
DC voltage change continuous1ms-99999ms
DC voltage change interval50ms-50000ms
Synchronization0°- 360°,1° step or random
Trigger modeAutomatic, manual or external
Optional functionAdditional module for voltage variation test and two DC mains
Peak Impulse Capacity of Simulator
Rated currentWithstand current impulse capacity
PFS 2210SD500A
PFS 2210SVD500A
PFS 2216SD500A
PFS 2216SVD500A
PFS 2232SD500A
PFS 2232SVD500A
PFS 0505D24V/50A,48V/100A
PFS 0510D24V/50A,48V/100A
PFS 1110D24V/50A,48V/100A,110V/220A
PFS 1120D24V/50A,48V/100A,110V/220A
PFS 1125D24V/50A,48V/100A,110V/220A
PFS 1130D24V/50A,48V/100A,110V/220A
PFS 1150D24V/50A,48V/100A,110V/220A
PFS 2210D24V/50A,48V/100A,110V/220A
PFS 2225D24V/50A,48V/100A,110V/220A
PFS 2250D24V/50A,48V/100A,110V/220A
Simulator with rated current no more than 16A meets the load capacity specified in IEC 61000-4-11
Rated currentLoad current capacity
PFS 2210SD
PFS 2210SVD
12A  AC/DC continuous current;
15A continuous 5s;
25Acontinuous 3s;
PFS 2216SD
PFS 2216SVD
18A  AC/DC continuous current;
20A continuous 5s;
40Acontinuous 3s;

Associated EMC Test Equipment