Power Fail Simulators

Quick Links

Information

Viewed products

3ctest S6/S10/S20 Series Compact Impulse Current Simulator (Up to 40kA) View larger

3ctest S6/S10/S20 Series Compact Impulse Current Simulator (Up to 40kA)

New

  • Single chip or PLC programmable controller with good reliability and intelligent control
  • Integrate design for easy and safety system
  • Color touch screen operation to monitor test operation
  • Constant current charging, stable and accurate charging, stable output
  • Flexible test setup for requirements of different tests
  • External CDN
  • Internal high-accuracy Roosevelt coil for data acquisition and panel output

Industries

  • Avionics
  • Broadcast
  • Communication
  • New energy
  • Medical
  • Military
  • Railway
  • Technology
  • Telecom

More details

Request Quote/More Info

PDF Downloads

Test Equipment Description

The 3ctest S6/S10/S20 Series is based on the third generation of intelligent multi-function comprehensive simulator. Set the test requirements on the parameter page and all the test procedure can be done automatically with the advantages of integrated system, intelligent control, easy-operation and time-saving. It fully meet the requirements of IEC 61643-1, GB18802.1, UL1449, YD-T1235[1].2 and TB/T 3074 surge standards for MOV, TVS and GDT surge protection device test and for mains surge protection test or scientific research.

As per

  • IEC 61643-1
  • GB18802.1
  • UL1449
  • YD-T1235[1].2
  • TB/T 3074
Technical Parameters
ModelS6 S10 S20
Output waveform8/20μs(other waveform please see attached table)
Front time T18μs±10%
Wave tail time T220μs±10%
Current peak Ip100A,1200A,6kA,10kA10kA,15kA,20kA20kA,30kA,40kA
Current output range10%-100%1kA~100%1kA~100%
Equivalent output impedance50Ω,5Ω,1Ω,0.5Ω1Ω,0.75Ω,0.5Ω1Ω,0.75Ω,0.5Ω
Charging voltageUp to 6kVUp to 10kVUp to 20kV
Internal grade energyI gradeIII grade, automatic switchIII grade, manual switch
Voltage polarity+/- (automatic switch)
Impulse interval10s~999s
Number of continuous impulse1~99
Charging voltage instabilityLess than 1%
Trigger modeAutomatic or manual, single trigger available
Trigger malfunction rateLess than 1%
Trigger range100% rated charging voltage
Measurement display resolutionBetter than 3%
Insulation strength≤500V RMS(common port COMMON to ground reference PE)
General Data
Power supplyAC220V±10%,50/60Hz,10A
Temperature-10-+40°
Humidity35%-85%RH(no condensation)
Ground resistanceNo more than 0.5Ω
Dimension19 inch 6U19 inch 22U19 inch 35U
WeightApprox. 35kgApprox. 120kgApprox. 200kg
No conductive dust, no fire or explosion danger, no corrosive metal and insulation air. Waveform of mains voltage is sine wave. The THD is <5%