RF Field Strength Probes & Meters

Quick Links

Information

Viewed products

PMM HP-032 Isotropic H-Field Sensor 100 kHz - 30 MHz View larger

PMM HP-032 Isotropic H-Field Sensor 100 kHz - 30 MHz

New

PMM HP-032 Isotropic H-Field Sensor 100 kHz - 30 MHz, 20 mA/m - 20 A/m, traceable calibration. Requires OR-03.

More details

Typically Stocked

Request Quote/More Info

Test Equipment Description

Features & Specifications of PMM HP-032:

PMM HP-032 Isotropic H-Field Sensor 100 kHz - 30 MHz, 20 mA/m - 20 A/m, traceable calibration. Requires OR-03.

  • Frequency range 0.1 - 30 MHz
  • Level range 0.01 - 20 A/m Overload > 40 A/m
  • Dynamic range > 60 dB Resolution 1 mA/m
  • Sensitivity 0.01 A/m
  • Absolute error @ 1 MHz 2 A/m 1 dB
  • Flatness (1 -25 MHz) 1 dB
  • Isotropicity 0.8 dB (typical 0.5 dB @ 1 MHz)
  • E-field rejection > 20 dB
  • Temperature error 0.05 dB/°C
  • Calibration Internal into E2PROM
  • Size 350 mm length, 133 mm diameter
  • Weight 400 g

Associated EMC Test Equipment