RF Conducted Immunity

Quick Links

Information

RF Conducted Immunity

 

The EMC Shop stocks RF conducted immunity test equipment and builds custom systems to fit the customer DUT and test requirements. Rent or buy a custom system taylored to your DUT and testing parameters. Software is included and custom test sequences will be generated, pre-programmed and calibrated by The EMC Shop staff prior to shipment.

 

Get Application Support, Pricing, Lead Time and More: CONTACT FORM


RF Conducted Immunity Test System


RF conducted testing is an efficient manner to test immunity along power and data lines up to 1 GHz. Common bandwidths range from 10kHz to 400 MHz, where the ~80 MHz range and higher acts as a good alternative to radiated immunity testing requiring high power RF amplifiers.

 

Video RF Conducted Immunity Test System Calibration

RF Conducted Immunity There are 27 products.

Subcategories

  • Bulk Current Injection (BCI) Probes

     

    Bulk Current Injection Testing         EMC/EMI Testing Services         Rent EMC Test Equipment          Antenna Testing

     

    Injecting low level RF signals and high frequency current into wires and cable bundles are a common requirement in ISO 11452-4, Mil-STD-461, RTCA/DO-160 and EN/IEC 61000-4-6. Bulk current injection probes are available in two styles, a window style for passing wires and cables through and a clamping style BCI probe for hard to access cable bundles or more intricate systems.

    Get Application Support, Pricing, Lead Time and More: Contact Form

    Bulk Current Injection (BCI) Probes Test Setup

    Bulk Current Injection (BCI) Probes Test Setup

  • EM Coupling Clamps

    The integrity of both communication and electrical lines within products of all shapes and sizes is important to address early in design stages. EM coupling clamps are used to monitor electrical and magnetic characteristics radiated from electrical/communication wires. Additional, you can generate electrical and magnetic fields using a clamp to inject distrubances onto the lines and evaluate their response. EM clamps are used to meet CISPR, IEC and other compliance standards to evaluate radio frequency disturbances on and around power or data lines.

    Get Application Support, Pricing, Lead Time and More: Contact Form

    EM Clamp Test Setup per IEC 61000-4-6

    EM Coupling Injection Clamp Test Setup per IEC 61000-4-6

    EM Injection Clamp Video Overview

per page
Showing 13 - 24 of 27 items
    • Conductive immunity test system with optional CDN, EM Clamp and or Current Injection Clamp
    • Meet IEC 61000-4-6 or MIL-STD-461 CS114
    • Easy to setup and use of software
    In Stock
    Request Quote/More Info
    • For EMC test according to the standards IEC/EN 61000-4-16 and IEC/EN 61000-4-19
    • Output module with 5A / 250 W
    • DC, sine, triangle and square waveforms external
    • Input adds to internal signal source Windows
    • Application software via USB port
    In Stock
    Request Quote/More Info
    • 100 kHz - 250 MHz Frequency Range
    • Turnkey software for IEC 61000-4-6
    • 25 Watt Integrated Amplifier
    • Computer Based System (USB controlled)
    • Self Calibration with CDN, EM Clamp or Injection Probe
    • RF generator, amplifier and RF Voltmeter usable as independent instruments
    • Connections: EUT "Fail", EUT monitoring by external multimeter
    Typically In Stock
    Request Quote/More Info
    • Conductive immunity test system with optional CDN, EM Clamp and or Current Injection Clamp
    • Easily sweep from 150 kHz to 230 MHz up to 10 Vrms
    • Meet IEC 61000-4-6 with easy plug and play system
    • Easy to setup and use with dedicated laptop/software
    Typically In Stock
    Request Quote/More Info
    • For use with one, two, three, or four unscreened balanced pairs
    • Refers schematic circuit example in CISPR 22/32 Figure D.3/G.3
    • Intended for connection to cable category 3 and 5
    • 1000BaseT and PoE application
    • Changeable pin-arrangements with RJ11 and RJ45
    In Stock
    Request Quote/More Info
  • Quick view
    $1,597.50 $2,130.00 -25%
    • For use with one unscreened balanced pairs
    • Refers schematic circuit example in CISPR 22/32 Figure D.1/G.1
    • Intended for connection to cable category 3 and 5
    • Changeable pin-arrangements with RJ11 and RJ45
    • Can be used as CDN for IEC/EN 61000-4-6 immunity tests
    $1,597.50 $2,130.00 -25%
    Reduced price!
    In Stock
    Request Quote/More Info
    • Most compact equipment
    • Supports BCI testing as per various standard requirements
    • Basic frequency range 9 kHz up to 400 MHz
    • Extendable frequency range up to 1 GHz
    • Built-in 110 W class A amplifier up to 400 MHz
    • Built-in RF switch to connect external amplifier
    • Built-in directional coupler
    • Built-in 3-channel power meter up to 1 GHz
    Typically In Stock
    Request Quote/More Info
    • 10 kHz–400 MHz Frequency Range
    • Bulk Current Injection (BCI) RF Conducted Immunity System
    • 100 Watts nominal

    Complete testing solutions to the following standards:

    In Stock
    Request Quote/More Info
    • 30 MHz - 1 GHz Frequency Range
    • RF Disturbance power measuring, according to CISPR 14 (EN 55014)
    • Aperture Diameter: 34.9 mm (1.37 inches)
    • Insetion Loss: 14 dB to 21 dB
    • Typically in stock with calibration and 3 Year warranty
    Typically In Stock
    Request Quote/More Info
    • Frequency Range 10 kHz to 400 MHz
    • Includes:
      • Pearson 8700i Current Injection Probe
      • Pearson 8705 Current Monitor
      • Pearson F-3 Calibration Jig
    • MIL-STD-461 CS114, CS115, CS116
    • DO-160 Section 21, rf CE (8705C)
    • AIAA S-121 Radio Frequency CS
    • NASA GSFC EMI Specs CE03, Bulk current emission
    • Automotive Chrysler Radio Frequency CE
    • John Deere Radio Frequency CE
    • BMW Radio Frequency CE
    • IEC / EN 61000-4-6
    • TR-102323 Radio Frequency CS
    In Stock
    Request Quote/More Info
    • Test procedure acc. IEC 61000-4-6 Ed. 4
    • Built-in amplifier saturation and linearity check
    • Built-in power amplifier 25 to 80 watts, 10 kHz to 400 MHz
    • Built-in power meter, 9 kHz to 1 GHz
    • Built-in dual directional coupler
    • Automatic calibration via built-in power meter
    • Connection for external amplifiers up to 1 GHz
    • USB-Interface
    • Software for Windows 7, Windows 8
    Typically In Stock
    Request Quote/More Info
    • Model CI00250A (75 Watt amplifier, 10 kHz – 250 MHz)
    • Model CI00400A (100 Watt amplifier, 10 kHz – 400 MHz)
    • Model CI00401A (150 Watt amplifier, 100 kHz – 400 MHz) 
    • EN/IEC 61000-4-6 Testing Solution
    In Stock
    Request Quote/More Info