Viewed products
Frequency range: 100 kHz to 1.6 GHz /...
Surge Simulation Pulse per IEC/EN...
New
Warning: Last items in stock!
Availability date:
Premium Spectrum Analyzer with 100 kHz to 1,6/3 GHz Bandwidth (easily upgradable by software option) and a 16,5 cm (6,5") color display. Upgradable with tracking generator and preamplifier.
You can create your R&S®HMS spectrum analyzer by combining a basic unit with any of three available options. In case of growing requirements, upgrade vouchers allow you to upgrade your instruments with all options at any point in time.
![]() | ![]() | ![]() |
This option activates all the functions that are required for EMC precompliance measurements. The preamplifi er option has been integrated into the new R&S®HMS-EMC option. | The frequency range is increased from 1.6 GHz to 3 GHz with this option. | This option activates the tracking generator in the instrument. |
Model Overview | R&S®HMS-X with EMC Option | R&S®HMS-X Basic Unit |
Amplitude measurement range | -114 dBm to +20 dBm | -104 dBm to +20 dBm |
DANL | typ. -135 dBm | typ. -104 dBm |
Resolution bandwidth | 100 Hz to 1 MHz, 200 kHz (-3 dB), 200 Hz, 9 kHz, 120 kHz, 1 MHz (-6 dB) | 10 kHz to 1 MHz, 200 kHz (-3 dB) |
Video bandwidth | 10 Hz to 1 MHz | 1 kHz to 1 MHz |
Not only do unexpected results in test labs during EMC compliance measurements translate into extra costs, quite often they also cause a substantial delay for your project.
Rohde & Schwarz offers effective and costeffi cient tools for EMC precompliance measurements which allow you to successfully prevent possible surprises before the actual onset of a problem.
Our HMExplorer software for your EMC measurements is included with every R&S®HMS-X spectrum analyzer with activated EMC option.
Rohde & Schwarz offers product sets for your EMC precompliance measurements, which include all necessary instruments to analyse typical EMC problems. Depending on your requirements, you can choose between a 1 GHz and a 3 GHz combination.
![]() | ![]() | ![]() |
Line impedance stabilization network for line conducted measurements LISN R&S®HM6050-2 | 1 GHz probe set R&S®HZ530 | 3 GHz probe set R&S®HZ540 (fi g. similar) |
1 GHz EMC-SET1
R&S®HMS-X Spectrum Analyzer – Specifications | |
Frequency Range | |
basic unit | 100 kHz to 1,6 GHz |
with HMS-3G (HV212) option | 100 kHz to 3 GHz |
Accuracy of the internal reference | ±2 x 10 -6 |
Temperature stability | ±2 x 10 -6 (0°C to +30 °C) |
Aging (per year) | ±1 x 10 -6 |
Frequency Counter (with HMS-EMC (HV213) option) | |
Resolution | 1 Hz |
Accuracy | ±(frequency x tolerance of reference) |
Span range | |
basic unit | 0 Hz (Zero Span), 100 Hz to 1.6 GHz |
with HMS-3G (HV212) option | 0 Hz (Zero Span), 100 Hz to 3 GHz |
Spectral purity, SSB phase noise (with HMS-EMC (HV213) option) | |
30 kHz from carrier (500 MHz, +20°C to +30 °C) | <-85 dBc/Hz |
100 kHz from carrier (500 MHz, +20°C to +30 °C) | <-100 dBc/Hz |
1 MHz from carrier (500 MHz, +20°C to +30 °C) | <-120 dBc/Hz |
Sweep time | |
f span = 0 Hz (zero span) | 2 ms to 100 s |
f span > 0 Hz 20 ms to 1000 s, min. | 20 ms per 600 MHz |
Resolution bandwidths (-3 dB) | |
basic unit | 10 kHz to 1 MHz (in 1 to 3 steps), 200 kHz |
with HMS-EMC (HV213) option | 100 Hz to 1 MHz (in 1 to 3 steps), 200 kHz |
Tolerance | |
f = 300 kHz | ±5 % typ. |
f > 1 MHz | ±10 % typ. |
Resolution bandwidths (-6 dB) | |
with HMS-EMC (HV213) option | CISPR: 200 Hz, 9 kHz, 120 kHz, 1 MHz |
Video bandwidths | |
basic unit | 1 kHz to 1 MHz (in 1 to 3 steps) |
with HMS-EMC (HV213) option | 10 Hz to 1 MHz (in 1 to 3 steps) |
Amplitude | |
Display range | Average noise level displayed up to +20 dBm |
Amplitude measurement range | |
basic unit | -104 dBm to +20 dBm (typ.) |
with HMS-EMC (HV213) option | -114 dBm to +20 dBm (typ.) |
Max. voltage at HF input | 80 V DC |
Max. power at HF input | 20 dBm (permanently), 30 dBm (temporarily for max. 3 min) |
Intermodulation-free range | |
TOI products, 2 x -20 dBm (-10 dBm ref. level) | 66 dB (typ.) (typ. +13 dBm third-order-intercept) |
signal distance =2 MHz | 60 dB (typ., +10 dBm TOI) |
signal distance >2 MHz | 66 dB (typ., +13 dBm TOI) |
DANL (displayed average noise level) (ref. level =-30 dBm, frequency range 10 MHz to 3 GHz) | |
10 kHz (RBW), 1 kHz (VBW) | -95 dBm (typ. -104 dBm) |
100 Hz (RBW), 10 Hz (VBW) with HMS-EMC (HV213) option | -115 dBm (typ. -135 dBm) |
Preamplifier with HMS-EMC (HV213) option | -124 dBm (typ.) |
Inherent spurious | |
ref.-level =-20 dBm, f >30 MHz, RBW =100 kHz | <-80 dBm |
Input related spurious (mixer level =-40 dBm) | |
Carrier offset | 1 MHz to 1.6 GHz: -70 dBc (typ.) |
1.6 GHz to 3 GHz with HMS-3G (HV212) option | -55 dBc (typ.) |
2nd harmonic receive frequency | |
Mixer level | -40 dBm -60 dBc (typ.) |
Level display | |
Reference level | -80 dBm to +20 dBm in 1 dB steps |
Display range | |
basic unit | 100 dB, 50 dB, 20 dB, 10 dB |
with HMS-EMC (HV213) option | linear |
level display error (ref. level -50 dBm, 20°C to 30 °C) | <1.5 dB (typ. 0.5 dB) |
Display scaling | |
logarithmical | dBm, dBµV, dBmV |
linear, with HMS-EMC (HV213) option | percentaged from reference level |
Measured curves | 1 curve and 1 memory curve |
Trace mathematics | A-B (curve-stored curve), B-A |
Detectors | |
basic unit | auto-, min/max. peak, sample, RMS, average |
with HMS-EMC (HV213) option | same as basic unit, quasi-peak in addition |
Marker and delta marker | |
Number of markers | 8 |
Marker functions | peak, next peak, minimum, center to marker, frequency, reference level to marker level, all marker on peak |
Marker display | |
basic unit | normal (level, logarithmic), delta marker, noise marker, normal (linear) |
mit HMS-EMC (HV213) option | (frequency) counter |
Connectors | |
HF Input | |
Connector | N socket |
Input impedance | 50 O |
VSWR (10 MHz to 3 GHz) | <1.5 (typ.) |
Tracking generator output (with R&S®HMS-TG/R&S®HV211) | |
Connector | N socket |
Output impedance | 50 O |
Frequency range | |
basic unit | 5 MHz to 1.6 GHz |
with HMS-3G (HV212) option | 5 MHz to 3 GHz |
Output level | -20 dBm to 0 dBm (in 1 dB steps) |
Trigger input | |
Connector | BNC socket (TTL) |
Trigger types | |
basic unit | free run, single trigger, external trigger |
with HMS-EMC (HV213) option | same as basic unit, video trigger in addition |
External reference input / output | |
Connectors | BNC socket |
Reference frequency | 10 MHz |
min. level (50 O) | 10 dBm |
Interfaces | |
for mass storage | 2x USB-host (type A), FAT16/32 |
for remote control | HO720 dual interface: RS-232 / USB-device (type B) |
Optional interfaces | HO732 dual interface: Ethernet (RJ45) / USB-device (type B) HO740 interface: IEEE-488 (GPIB) |
Video output | DVI-D (480p, 60Hz), HDMI compliant |
Save and recall | on internal file system (up to 10 device settings) or external USB memory (max. 4 GB) |
Additional connectors | |
Supply output for field probes | 6 V DC, max. 100 mA (2.5 mm DIN jack) |
Audio output | 3.5 mm DIN jack |
Demodulation | AM and FM (via internal speaker) |
General Characteristics | |
Display | |
screen size / type | 16.5 cm (6,5”) VGA color TFT |
resolution | 640 x 480 (LED) |
Power supply | |
AC supply | 105 V to 253 V, 50 Hz to 60 Hz, CAT II |
power consumption | 40 W (typ.) |
Safety | safety class I (EN61010-1) |
Temperature | |
operating temperature range | +5 °C to +40 °C |
storage temperature range | -20 °C to +70 °C |
Rel. humidity | 5% to 80% (without condensation) |
Mechanical data | |
dimensions (W x H x D) | 285 x 175 x 220 mm |
weight | 3.6 kg |