Viewed products
High reliability proven GaAs design...
New
Typical Lead Time 4 - 6 Weeks
Warning: Last items in stock!
Availability date:
Frequency Range | 10-1000MHz |
Gain | 49dB Min |
Input | Input VSWR 2:1 (Max) |
Output | Rated Output Power 70W Min (100W typical 10-500MHz) Output Power at 1dB Gain Compression 60W Min (80W typical 10-500MHz) |
Maximum Continuous Power | Rated Output Power 70W Min (100W typical 10-500MHz) Output Power at 1dB Gain Compression 60W Min (80W typical 10-500MHz) |
Impedance | 50 Ohms |
Connector | RF Connector Style Type N Female Safety Interlock 2 x BNC, S/C and O/C to Mute |
Dimensions | 19 inch, 4U Case, 550mm Deep |
VSWR | Input VSWR 2:1 (Max) |
AC Power Adapter | Supply Voltage 85-264V AC Supply Frequency Range 45-63Hz Supply Power 500VA (Max) |
Weight | 15kg |
The Vectawave VBA1000-70 is a member of the 10-1000MHz high power amplifiers, designed primarily for EMC applications.
Like all of the products of the VBA1000 series, it is based on the unique GaAs technology, offering the user the benefits of higher linearity, ruggedness and efficiency than its silicon-based counterparts and lower cost than the more recent GaN additions to the marketplace.
Electrical
Frequency Range (Instantaneous) 10-1000MHz
Rated Output Power 70W Min (100W typical 10-500MHz)
Output Power at 1dB Gain Compression 60W Min (80W typical 10-500MHz)
Gain 49dB Min
Third Order Intercept Point (see note 1) 58dBm
Gain variation with Frequency ±3dB
Harmonics at 60W Output Power Better than -20dBc
Output Impedance 50 Ohms
Stability Unconditional
Output VSWR Tolerance (see note 2) Infinity:1
Input VSWR 2:1 (Max)
Supply Voltage 85-264V ac
Supply Frequency Range 45-63Hz
Supply Power <500VA (Max)
Mains Connector IEC320
Mechanical
RF Connector Style Type N Female
Safety Interlock 2 x BNC, S/C and O/C to Mute
USB/GPIB Interface Optional
Dimensions 19 inch, 4U Case, 550mm Deep
Mass 15kg
Operating Temperature Range 0-40°C
Case Style Options Rack mount with Front or Rear panel connectors
Bench mount with Front panel connectors
Regulatory Compliance
Conducted and Radiated Emissions EN61326 Class A
Conducted and Radiated Immunity EN61326:1997 Table 1
Safety EN61010-1