Rohde & Schwarz HM6050-2 Line Impedance Stabilization Network (LISN)

New

  • Frequency Range: 9 kHz to 30 MHz
  • Current Rating: 16 Amps
  • Fully Compliant with CISPR 16-1-2

More details

Typically In Stock

Request Quote/More Info

Specifications

Voltage Rating230 Volts
Frequency Range10 kHz to 30 MHz
Standards MetCISPR 16-1-2
RF ConnectorRF Measurement Port 50Ω - N-Type (female)
Inductors 50 µH
Mains & EUT ConnectionsSchuko plug socket
Current Rating16 Amperes
Application/Test TypePower Line Conducted Emissions Tests
Insertion loss10dB
Dimensions285 x 125 x 380mm
Weight6 kg

Test Equipment Description

Rohde & Schwarz HM6050-2 Description

The Line Impedance Stabilization Network HM6050-2 is designed for compliance level measurements of conducted EMC emissions. The unit complies with VDE 0876 and CISPR regulations and can be operated manually or PC controlled via the built in RS232 interface. It is designed and built using air core inductors to avoid saturation at peak current loads.

Single-phase V-network to measure line-conducted interferences from 9 kHz to 30 MHz (based on CISPR 16)

  • US safety plug, 120 V
  • Selectable transient limiter
  • Artificial hand connector
Frequency Range:9 kHz to 30 MHz
Impedance Characteristics:Z = 50 Ω II (50 μH + 5 Ω), Error <20% under terms of VDE 876T1
Max. Current:16 A
Line Voltage/FrequencyUS Version: 115 V, 50 to 60 Hz
Artificial Hand:220 pF + 511 Ω
PE (selectable):50 μH II 50 Ω

Line cord, Operating manual included

See Transient LimitersAttenuators and Transient Generators