| Frequency Range | 0.1 MHz - 18 GHz |
| Standards Met | IEC/EN 61000-4-3 |
| Application/Test Type | Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF rooms for radiated immunity testing. |
| RF Field Probes E-Field | |
| Parameter | Value |
| Sensors | see our EMC Test Design Probes |
| Measurement Mode | X-Y-Z axis simultaneous sampling |
| Sampling Rate | 22 to 0.03 Samples/s depending on filter settings |
| Digital Filtering | Low-pass 2.3 to 28 Hz; 80 dB notch 50/60 Hz |
| Battery | 3V, 5 mA/h, Li-Mn rechargeable |
| Operation Time | 80 hours @ 0.4 S/s, 28 Hz filter; 60 hours @ 5 S/s, 28Hz filter |
| Recharging Time | 48 hours for full operation time Partial charging allowed (8 hrs recharging allows 12 hrs operation @ 5 S/s 1 hr recharging allows 5 hrs operation @ 0.4 S/s |
| Flatness | Frequency correction OFF: 1 to 150 MHz: 0.8 dB; 0.5 to 6000 MHz: 1.6 dB; 0.3 to 7500 MHz: 3.2 dB; Frequency correction ON: typically 0.3 to 7500 MHz: 0.4 dB |
| Dynamic Range | 0.14 to 140 V/m; 60 dB single range |
| Overload | 300 V/m |
| Internal Data Memory | Serial nr. - Calibration factors & date Firmware version |
| Communication | Bidirectional fiber optic link |
| PC Software | Displays field, temperature, battery Sampling, filters, averaging, frequency setting Manual data logging as text file |
| Probe Holder Tip | 1/4 20 UNC female |
| Battery Voltage Reading Resolution | 10 mV |
| Temperature Reading Resolution | 0.1 °C |
| Resolution | 0.01 V/m |
| Dimensions | 53mm (2.08 inches) |
| Weight | 23 grams (0.8 ounce) |
The Model RFP-05M operates with and stores the data using multiple probes, both current one and future model designs.
It has a large dynamic range with auto-ranging and auto-zero functions, offering high accuracy and simple operation.
It features advanced programmable data sampling with time and space averaging, and also allows monitoring and recording of time-variable signals. Internal data logging via a removable flashcard memory offers programmable and virtually unlimited data storage. A serial bidirectional data port and IR remote control facilitates PC data transfer and wireless instrument control. A bright color OLED display with excellent visibility can display only the information important to the user. Model RFP-05M’s portable lightweight design with detachable isotropic probe and two-cell AA primary or rechargeable battery offers flexibility and convenience for field use.
Model RFP-05M is a development of the model RFP-05 and has two main advantages:
RFP-05M can operate with multiple probes, both current and future models.
Meter RFP-05M with probes (can support up to 4 probes at the same time):
US NIST (USA National Institute of Standards) / UK NPL (UK National Physical Laboratory) traceable certificate is supplied with every unit.