RF Field Strength Probes & Meters

Quick Links

Information

Viewed products

HFP50M Isotropic Magnetic Field Probe 500 kHz - 50 MHz View larger

MFP50M Isotropic Magnetic Field Probe 500 kHz - 50 MHz

New

  • Covers frequencies of major industrial, boradcast and telecommunication sources
  • Eliminates need for 2 probes
  • 500 KHz -50 MHz 
  • Field strength: 0.05 - 20 A/m

More details

Typically In Stock

Request Quote/More Info

PDF Downloads

MFP50M Datasheet

MFP50M Isotropic Magnetic Field Probe 500 kHz - 50 MHz

PDF Downloads (343.28k)

Specifications

Frequency range500 kHz - 50 MHz
Dimensions (LxD): 9.0x2.25 inch, 230x58 mm
Weight0.2 lb, 100 g

Test Equipment Description

MFP50M Isotropic Magnetic Field Probe 500 kHz - 50 MHz Details

State of the art MFP50M Isotropic Magnetic Field Probe is used for monitoring field strengths while performing magnetic immunity tests per IEC 61000-4-8IEC 61000-4-9 or IEC 61000-4-10 or can be used in the field to evaluate exposure. The MFP50M Isotropic Magnetic Field Probe can also used to calibrate magnetic field generators used in compliance testing.

The MFP50M Probe covers the frequencies of major industrial, broadcast and telecommunication sources, has flat response in the pass band 2-50 MHz and usable response to 500 KHz (with correction factors), eliminating the typical need for two probes (active and passive). MFP50M probe is very compact, rugged and offers good magnetic field overload capability and pick up suppression of the out-of-band electric and magnetic fields.

  • Sensor: 3-Axial diode based isotropic sensor with orthogonal broadband loops
  • High sensitivity: 0.05 A/m
  • Linearity: +/- 0.5 dB
  • Dynamic range: >50 dB (single range)
  • Withstands continuous magnetic field 30 A/m
  • Frequency response (referred to 27.1 MHz):
    • 2 MHz-50 MHz (+0/- 1 dB)
  • Frequency response (with correction factors):
    • 500 KHz-50 MHz (+/- 1 dB)
  • Rotational isotropicity: +/- 0.6 dB
  • Calibration accuracy (at specified freq.) <0.5 dB
  • E field suppression: 15 dB (at 13.56 MHz)
  • Temperature: 5-40 °C
  • Humidity: RH 10-90%, non-condensing
  • Temperature error: <0.05 dB/°C (field > 0.1 A/m)
  • UK NPL or NIST traceable calibration
  • Small size: LxD: 9.0x2.25 inch, 230x58 mm
  • Weight: 0.2 lb, 100 g
  • Operates with RFM meter
  • Designed and made in the USA

Associated EMC Test Equipment