Viewed products
10 kHz - 9.25 GHz Frequency Range Up...
New
Typically Stocked
Warning: Last items in stock!
Availability date:
Frequency Range | 10 kHz to 9.25 GHz |
Application/Test Type | Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF rooms for radiated immunity testing. |
RF Field Probes E-Field | |
Parameter | Value |
Sensors | Six monopoles |
Measurement Mode | X-Y-Z axis simultaneous sampling |
Sampling Rate | 22 to 0.03 Samples/s depending on filter settings |
Digital Filtering | Low-pass 2.3 to 28 Hz; 80 dB notch 50/60 Hz |
Battery | 3V, 5 mA/h, Li-Mn rechargeable |
Operation Time | 80 hours @ 0.4 S/s, 28 Hz filter; 60 hours @ 5 S/s, 28Hz filter |
Recharging Time | 48 hours for full operation time Partial charging allowed (8 hrs recharging allows 12 hrs operation @ 5 S/s 1 hr recharging allows 5 hrs operation @ 0.4 S/s |
Flatness | Frequency correction OFF: 0.1 to 150 MHz: 0.4 dB; 0.05 to 6000 MHz: 1.6 dB; 0.03 to 7500 MHz: 3.2 dB; Frequency correction ON: typically 0.05 to 7500 MHz: 0.4 dB |
Dynamic Range | 0.5 to 500 V/m; 60 dB single range |
Overload | 1,000 V/m |
Internal Data Memory | Serial nr. - Calibration factors & date Firmware version |
Communication | Bidirectional fiber optic link |
PC Software | Displays field, temperature, battery Sampling, filters, averaging, frequency setting Manual data logging as text file |
Probe Holder Tip | 1/4 20 UNC female |
Temperature Reading Resolution | 0.1 °C |
Resolution | 0.01 V/m |
Dimensions | 53mm (2.08 inches) |
Weight | 23 grams (0.8 ounce) |
The all-in-one that sets the standard for miniature optically coupled broadband E-field isotropic probes. Exceptionally small-sized spherical symmetrical configuration, lightweight and miniaturized electronics combined with excellent RF characteristics make the Narda PMM EP-601 isotropic RF electric field probe to 500 V/m is the ideal solution for all EMC/EMI applications (chambers and TEM/GTEM cells), biology and materials research and wherever fast and accurate measurements with negligible or minimum interference of the probe to the field under measure are essential. Accredited calibration on request.
This is a small unobtrusive electric field probe for the measurement of radiated electric field during EN61000-4-3 testing in enclosed chambers or GTEMs. As the immunity specs are now going up to 6GHz the range of this sensor is ideal. It essentially consists of the 'Orthogonal' miniature sensor. The sensor head is then connected via a duplex fibre optic cable interfacing into a fibre to RS232 adapter. A further interface then converts the RS232 to a USB connector. This then connects directly with any laptop with the PMM display software. The hired kit comes with a CD for installing on a customer’s PC. We have also written the driver enabling it to be used with one of our laptops and integrated into our Em-CIM conducted/radiated immunity software package. The probe head itself consists of three miniature dipoles 52mm from end to end. A 10m fibre optic cable will then connect the probe to the RS232 interface module.