SPECIFICATIONS | ||||
Mechanical Data | Loop Sensor MGA_LS040 | Radiating Loop MGA_RL120 | Loop Sensor MGA_LS133 | Loop Sensor / Radiating Loop MGA_RLS133 |
Diameter | 40 mm | 120 mm | 133 mm | 133 mm |
Body material | PVC | MDF | MDF | MDF |
Wire | 7-41 Litz wire | 2.0 mm copper wire | 7-41 Litz wire | 0.25 mm² Litz wire |
Number of turns | 51 | 20 | 36 3 | 6 |
Number of layers | 1 | 4 | 4 | 4 |
Shielding | Electrostatic | none | Electrostatic | Electrostatic |
Distance to EUT | 5 cm | 5 cm | 7 cm | 10 cm / 5 cm |
Connector at coil | Speakon | 4 mm MC socket | Speakon | Speakon |
Connector at cable | XLR | 4 mm MC plug | XLR | XLR/4 mm MC plug |
Coil factor (50 mm) | --- | 76,3 1/m | --- | 138,5 1/m |
Electrical Data | ||||
Correction factor | see calibration sheet (50 Ω / 600 Ω / 1MΩ) | --- | see calibration sheet (50 Ω / 600 Ω / 1MΩ) | see calibration sheet (50 Ω / 600 Ω / 1MΩ) |
DC resistance | ~ 4,5 Ω | ~ 0,05 Ω | ~ 10 Ω | ~ 1,1 Ω |
Inductance | ~ 130 µH | ~ 120 µH | ~ 340 µH | ~ 340 µH |
Resonant frequency | --- | > 1.8 MHz | --- | > 0.9 MHz |
Frequency range | 10 Hz - 1 MHz | DC - 500 kHz | 10 Hz - 1 MHz | DC / 10 Hz - 500 kHz |
Nominal current | --- | 15 A | --- | 5 A |
General Data | ||||
Connecting cable | Microphone cable | Litz wire 2 x 1.5mm² | Microphone cable | Microphone cable / Litz wire 2 x 1.5mm² |