Viewed products
Rigid construction Inside complete...
New
Standards
Warning: Last items in stock!
Availability date:
Reverberation chambers (RCs) are modern EMC test environments in addition to the established methods like semi- or full anechoic rooms, open area test sites or (G)TEM cells. They can be used for emission and immunity testing. A reverberation chamber basically consists of a shielded room and a stirrer which changes (“stirs”) the electromagnetic field inside the chamber. The chamber itself behaves like a multi mode resonator.
System Overview

Media Feed-Through Connectors and Panel
| Stirrer control program | Compliance 5 Software: Stirrer Settings |
![]() | ![]() |
| Specifications | |
| Chamber in accordance to | IEC 61000-4-21:Ed.2, MIL461F, RTCA DO160F, Automotive (GM, Ford,…) and others |
| Dimension chamber (LxDxH in m) | 1.5 x 0.8 x 1.0 |
| Dimension over all (LxDxH in m) | 1.6 x 0.9 x 1.1 |
| Working volume size (LxDxH in m) | 0.5 x 0.3 x 0.5 |
| Recommended max. EUT size (LxDxH in m) | 0.3 x 0.3 x 0.3 |
| Material of the chamber walls | aluminum |
| Frequency range | 0.8 to 18 GHz |
| Typical shielding effectiveness | ≥80 dB (0.8 to 18 GHz) |
| Door size, chamber (LxH in m) | 0.65 x 0.48 |
| Medial panel size (LxH in m) | 0.5 x 0.5 |
| Weight | approx. 96 kg |