Teseq (Schaffner)

Quick Links

Information

Viewed products

Teseq RC Chamber 2XS Reverberation Chamber

New

  • Rigid construction
  • Inside complete flat surface (no connection elements as used for pan-type or sandwich
  • construction) for optimum power and field performance
  • Outside reinforced frame for optimum stability
  • Plug-and-play chamber – fully tested and ready to use – no on-site assembling necessary
  • In addition wheels for easy transportation – mobile design
  • Stirrer control unit with remote interface and software
  • Driver for test house software Compliance 5I/E
  • Open source commands for easy implementation of the stirrer controller in any other software
  • Applications in the automotive, military and commercial market
  • Supplied with two feed-throughs type N, media panel, Stirrer Control Program and stirrer with motor control and filtering
  • Optional power and signal filter available

Standards

  • IEC/EN 61000-4-21
  • MIL STD 461
  • RTCA/DO 160
  • ISO 11452-11
  • SAE J1113-27

More details

Request Quote/More Info

PDF Downloads

Test Equipment Description

Reverberation chambers (RCs) are modern EMC test environments in addition to the established methods like semi- or full anechoic rooms, open area test sites or (G)TEM cells. They can be used for emission and immunity testing. A reverberation chamber basically consists of a shielded room and a stirrer which changes (“stirs”) the electromagnetic field inside the chamber. The chamber itself behaves like a multi mode resonator.

System Overview

System Overview

Media Feed-Through Connectors and Panel

  • Standard connectors: 4x N female type connectors, 2x FSMA optical connectors, 1x FC optical connector (used for e.g. HI6105 field probes) and 1x ST optical connector (used for e.g. HI6105 field probes)
  • Media panel (size 0.5 m x 0.5 m) for customer specific filters
Stirrer control programCompliance 5 Software: Stirrer Settings
Stirrer Control ProgramCompliance 5 Software: Stirrer Settings

Specifications
Chamber in accordance toIEC 61000-4-21:Ed.2, MIL461F, RTCA DO160F, Automotive (GM, Ford,…) and others
Dimension chamber (LxDxH in m)1.5 x 0.8 x 1.0
Dimension over all (LxDxH in m)1.6 x 0.9 x 1.1
Working volume size (LxDxH in m)0.5 x 0.3 x 0.5
Recommended max. EUT size (LxDxH in m)0.3 x 0.3 x 0.3
Material of the chamber wallsaluminum
Frequency range0.8 to 18 GHz
Typical shielding effectiveness≥80 dB (0.8 to 18 GHz)
Door size, chamber (LxH in m)0.65 x 0.48
Medial panel size (LxH in m)0.5 x 0.5
Weightapprox. 96 kg