10 kHz - 250 MHz RF Amplifiers

Quick Links

Information

Viewed products

Com-Power ACS-181 150 kHz - 80 MHz 100W Power Amplifier View larger

Com-Power ACS-181 150 kHz - 80 MHz 100W Power Amplifier

New

  • 150 kHz - 80 MHz
  • 100 Watts
  • Immunity Testing
  • IEC 61000-4-6 testing
  • Automatic Safety Shutoff

More details

Typical Lead Time 4 - 6 Weeks

Request Quote/More Info

PDF Downloads

Test Equipment Description

Com-Power ACS-181 series broadband amplifiers operate from 150 kHz to 80 MHz. This amplifier can be used for EMI immunity testing that requires generating electric fields. This small and lightweight amplifier utilizes class AB linear power devices that provide high gain, and wide dynamic range. By employing advanced components, the Com-Power ACS-181 amplifier is able to achieve high efficiency operation and reliability.


The ACS-230-series models are engineered to provide high gain, with excellent efficiency and reliability, at an unbeatable price. It complementing Com-Power's full line of Coupling/Decoupling Networks (CDN's) and related test and calibration accessories. it easily achieves 3 Vrms or 10 Vrms test levels with any com¬pliant coupling network (CDN, EM Clamp, Injection Probe, etc.) The ACS-230-series amplifiers complies with all required technical specifications for IEC 61000-4-6 compliance testing, yet its low cost makes it affordable even as part of a pre-compliance testing solution.

These amplifiers are individually tested to make sure that they meet the technical requirements given in IEC-61000-4-6 before shipment. The amplifiers can be also supplied with a matched CDN and test accessories for a complete solution. Optional software to automate the conducted immunity testing is also available. All Com-Power products come with a 3 year warranty.

Application

The required test levels per IEC 61000-4-6 (given in the table below) that can be achieved using the ASC series power when properly configured with a compliant coupling decoupling network from Com-Power or another manufacturer. Please refer to IEC 61000-4-6 for information on test setup, procedures and test accessories needed.

Test Level Volts (V0)umr (150) Voltsumr (150) Volts (dBm)
10.167-2.5
20.57
31.6717.5

Vo = Open circuit voltage in 150Ω system.
umr = Voltage level measured at the output of the 150Ω to 50Ω adapter (ADA-515).

Specifications
Frequency Range150 kHz to 80 MHz
Rated Power Output100 watts into 2:1 VSWR
Gain50 dB ±2 dB
Input for rated output0 dBm (typical)
Automatic Safety Shut-off125 watts ± 2
Power Output @ 1 dB Compression PointN/A
Input
Impedance50 ohms (nominal)
VSWR1.7 (maximum)
Input Signal Modulation CompatibilityAM, FM, or Pulse modulation
ConnectorType N on Front Panel
Output
Impedance50 ohms (nominal)
VSWR1.7 (maximum)
Harmonic distortion-15 dBc at 75 watts
Mismatch ToleranceAutomatic Safety Shut-off @ VSWR >5
ConnectorType N on Front Panel
Power (Universal)
AC, Single Phase100-240 VAC 50/60 Hz
Display and InterfacesUSB Remote Interface
Front Panel Display (Column 1)Amplifier Current measurement Data
Front Panel Display (Column 2)Amplifier Temperature measurement data
Front Panel Display (Column 3)Load VSWR, RF Power Input/Output, Gain
Remote Interlock (optional)2-pin DIN
Mechanical
CoolingForced air (self-contained fans)
Size19” Rack 4U
Weight50 lbs (22.6 kg)
Operating Temperature Range0° C to +40° C

Associated EMC Test Equipment