Viewed products
150 kHz - 80 MHz 100 Watts Immunity...
2-1000 V/m Accurate field...
New
Typical Lead Time 4 - 6 Weeks
Warning: Last items in stock!
Availability date:
The ACS-230-series models are engineered to provide high gain, with excellent efficiency and reliability, at an unbeatable price. It complementing Com-Power's full line of Coupling/Decoupling Networks (CDN's) and related test and calibration accessories. it easily achieves 3 Vrms or 10 Vrms test levels with any com¬pliant coupling network (CDN, EM Clamp, Injection Probe, etc.) The ACS-230-series amplifiers complies with all required technical specifications for IEC 61000-4-6 compliance testing, yet its low cost makes it affordable even as part of a pre-compliance testing solution.
These amplifiers are individually tested to make sure that they meet the technical requirements given in IEC-61000-4-6 before shipment. The amplifiers can be also supplied with a matched CDN and test accessories for a complete solution. Optional software to automate the conducted immunity testing is also available. All Com-Power products come with a 3 year warranty.
Application
The required test levels per IEC 61000-4-6 (given in the table below) that can be achieved using the ASC series power when properly configured with a compliant coupling decoupling network from Com-Power or another manufacturer. Please refer to IEC 61000-4-6 for information on test setup, procedures and test accessories needed.
| Test Level Volts (V0) | umr (150) Volts | umr (150) Volts (dBm) |
| 1 | 0.167 | -2.5 |
| 2 | 0.5 | 7 |
| 3 | 1.67 | 17.5 |
Vo = Open circuit voltage in 150Ω system.
umr = Voltage level measured at the output of the 150Ω to 50Ω adapter (ADA-515).
| Specifications | |
| Frequency Range | 150 kHz to 80 MHz |
| Rated Power Output | 100 watts into 2:1 VSWR |
| Gain | 50 dB ±2 dB |
| Input for rated output | 0 dBm (typical) |
| Automatic Safety Shut-off | 125 watts ± 2 |
| Power Output @ 1 dB Compression Point | N/A |
| Input | |
| Impedance | 50 ohms (nominal) |
| VSWR | 1.7 (maximum) |
| Input Signal Modulation Compatibility | AM, FM, or Pulse modulation |
| Connector | Type N on Front Panel |
| Output | |
| Impedance | 50 ohms (nominal) |
| VSWR | 1.7 (maximum) |
| Harmonic distortion | -15 dBc at 75 watts |
| Mismatch Tolerance | Automatic Safety Shut-off @ VSWR >5 |
| Connector | Type N on Front Panel |
| Power (Universal) | |
| AC, Single Phase | 100-240 VAC 50/60 Hz |
| Display and Interfaces | USB Remote Interface |
| Front Panel Display (Column 1) | Amplifier Current measurement Data |
| Front Panel Display (Column 2) | Amplifier Temperature measurement data |
| Front Panel Display (Column 3) | Load VSWR, RF Power Input/Output, Gain |
| Remote Interlock (optional) | 2-pin DIN |
| Mechanical | |
| Cooling | Forced air (self-contained fans) |
| Size | 19” Rack 4U |
| Weight | 50 lbs (22.6 kg) |
| Operating Temperature Range | 0° C to +40° C |