Frequency Range | 150kHz - 230MHz |
Gain | 50dB Min |
Input | Input VSWR 2:1 (Max) |
Output | Rated Output Power 80W Min (90W typical) Output Power at 1dB Gain Compression 70W Min (80W typical) |
Impedance | 50 Ohms |
Connector | RF Connector Style Type N Female Safety Interlock 2 x BNC, S/C and O/C to Mute |
Dimensions | 19 inch, 3U Case, 440mm Deep |
VSWR | 2:1 (Max) |
AC Power Adapter | Supply Voltage 85-264V ac Supply Frequency Range 47-63Hz Supply Power 400VA (Max) |
Weight | 13kg |
The VBA230-80 is a member of the 150kHz- 230MHz high power amplifiers, designed primarily for EMC applications.
Like all our products of the VBA230 series, it is based on rugged push-pull MOSFET technology, for extra even order harmonic suppression.
The amplifier operates in class A, the benefits for EMC applications being very low distortion and tolerance of 100% mismatch. Fold-back protection is neither fitted nor needed! This makes it supremely suited for very demanding transducer requirements.
Electrical
Frequency Range (Instantaneous) 0.15-230MHz
Rated Output Power 80W Min (90W typical)
Output Power at 1dB Gain Compression 70W Min (80W typical)
Gain 50dB Min
Third Order Intercept Point (see note 1) 58dBm
Gain variation with Frequency ±2dB
Harmonics at 70W Output Power Better than -20dBc
Output Impedance 50 Ohms
Stability Unconditional
Output VSWR Tolerance (see note 2) Infinity:1
Input VSWR 2:1 (Max)
Supply Voltage 85-264V ac
Supply Frequency Range 47-63Hz
Supply Power <400VA (Max)
Mains Connector IEC320
Mechanical
RF Connector Style Type N Female
Safety Interlock 2 x BNC, S/C and O/C to Mute
USB/GPIB Interface Optional
Dimensions 19 inch, 3U Case, 440mm Deep
Mass 13kg
Operating Temperature Range 0-40°C
Case Style Options Rack mount with Front or Rear panel connectors
Bench mount with Front panel connectors
Regulatory Compliance
Conducted and Radiated Emissions EN61326 Class A
Conducted and Radiated Immunity EN61326:1997 Table 1
Safety EN61010-1