10 kHz - 250 MHz RF Amplifiers

Quick Links

Information

Viewed products

Com-Power ACS-230-50W Power Amplifier 150 kHz - 230 MHz View larger

Com-Power ACS-230-50W 150 kHz to 230 MHz 50W Power Amplifier

New

  • 150 kHz - 230 MHz
  • 50 Watts
  • IEC 61000-4-6 testing
  • 3 Year Warranty

More details

Typically In Stock

Request Quote/More Info

PDF Downloads

Test Equipment Description

The ACS-230-50W is part of Com-Power's series of broadband RF amplifiers; diverse in application, yet specifically geared for use in EMC immunity testing applications.

The ACS-230-50W model was engineered to provide high gain, with excellent efficiency and reliability, at an unbeatable price. It has 47 dB gain, 50 Watt nominal power output., The ACS-230-50W amplifier complies with all required technical specifications for IEC 61000-4-6 compliance testing, yet its low cost makes it affordable even as part of a pre-compliance testing solution.

These amplifiers are individually tested to make sure that they meet the technical requirements given in IEC 61000-4-6 before shipment. The amplifiers can be also supplied with a matched CDN and test accessories for a complete solution. Optional software to automate the conducted immunity testing is also available. All Com-Power products come with a 3 year warranty.

Application

The required test levels per IEC 61000-4-6 (given in the table below) that can be achieved using the ASC series power when properly configured with a compliant coupling decoupling network from Com-Power or another manufacturer. Please refer to IEC 61000-4-6 for information on test setup, procedures and test accessories needed.

Test Level Volts (V0)umr (150) Voltsumr (150) Volts (dBm)
10.167-2.5
20.57
31.6717.5

Vo = Open circuit voltage in 150Ω system.
umr = Voltage level measured at the output of the 150Ω to 50Ω adapter (ADA-515).

Specifications
Frequency Range150 kHz to 230 MHz
Rated Power Output50 watts into 2:1 VSWR
Gain47 dB ±2 dB
Input for rated output0 dBm (typical)
Automatic Safety Shut-off50 watts ± 2
Power Output @ 1 dB Compression PointN/A
Input
Impedance50 ohms (nominal)
VSWR1.7 (maximum)
Input Signal Modulation CompatibilityAM, FM, or Pulse modulation
ConnectorType N on Front Panel
Output
Impedance50 ohms (nominal)
VSWR1.7 (maximum)
Harmonic distortion-17 dBc at 50 watts
Mismatch ToleranceAutomatic Safety Shut-off @ VSWR >7
ConnectorType N on Front Panel
Power
AC, Single Phase100-240 VAC 50/60 Hz
Display and Interfaces
InterfaceUSB Remote Interface
Front Panel Display (Column 1)Current
Front Panel Display (Column 2)Temperature
Front Panel Display (Column 3)Load VSWR, RF Power Input/Output, Gain
Remote Interlock (optional)2-pin DIN
Mechanical
CoolingForced air (self-contained fans)
Size19” Rack 4U
Weight50 lbs (22.6 kg)
Operating Temperature Range0° C to +40° C

Associated EMC Test Equipment