10 kHz - 400 MHz RF Amplifiers

Quick Links

Information

Viewed products

Amplifier Research 50U1000, 50 Watts CW, Class A Solid State RF Power Amplifer View larger

Amplifier Research 50U1000, 50 Watts CW, Class A Solid State RF Power Amplifier

Rental

  • Fresh Output Curve Provided
  • Output: 50 Watts CW 
  • Frequency Range: 10kHz-1000MHz
  • Class A
  • Connectors:
    • RF In: N(f)-type
    • RF Out: N(f)-type

More details

Request Quote/More Info

PDF Downloads

Specifications

Frequency Range10kHz-1000MHz
RF Connector Type N female
GainGAIN (at maximum setting): 47 dB minimum GAIN ADJUSTMENT (Continuous Range) : 20 dB minimum
RF Input Voltage1.0 milliwatt maximum for rated output
Impedance50 ohms
InputPRIMARY POWER (Universal; selected automatically): 100-240 VAC, 50/60Hz, 250 watts
OutputPOWER OUTPUT @ 3dB COMPRESSION: Typical: 70 watts, Minimum: 50 watts POWER OUTPUT @ 1dB COMPRESSION: Typical: 60 watts, Minimum: 45 watts
Flatness± 1.5 dB
DimensionsWith cabinet: 50.3 x 15.5 x 55.1 cm (19.8 x 6.1 x 21.7 in) Without Cabinet: 48.3 x 13.2 x 55.1 cm (19 x 5.2 x 21.7 in)
WeightWith Cabinet 17.7 kg (41 lbs) Without Cabinet 9.5 kg (23 lbs)

Test Equipment Description

How to Order Online:

  • Click "Add to Cart" above
  • Register or Check Out as a Guest
  • Select Shipping Method (use "My Account" and input your account # and method)
  • Order Confirmation and Tracking Info Follows

The Amplifier Research Model 50U1000 is a solid-state, selfcontained, air-cooled, broadband amplifier designed for applications where instantaneous bandwidth, high gain and linearity are required.

Available in a stylish, contemporary cabinet for benchtop use or with cabinet removed for rack mounting. The Model 50U1000, when used with a sweep generator, will provide a minimum of 50 watts of RF power.

Included is a front panel gain control which permits the operator to conveniently set the desired output level. The 50U1000 is protected from RF input overdrive by an RF input leveling circuit which controls the RF input level to the RF amplifier first stage when the RF input level is increased above 0dBm. The RF amplifier stages are protected from over-temperature by removing the DC voltage to them if an overtemperature condition occurs due to coolingblockage or fan failure.

The front panel indicates the operate status and fault conditions if an over-temperature or power supply fault has occurred. The unit can be returned to operate when the condition has been cleared. All amplifier control functions and status indications are available remotely through the optional Remotes Package. The Remotes Package includes GPIB/IEEE-488 format, RS-232 hardwire and fiber optic, USB, and Ethernet. The bus interface connector is located on the back panel and positive control of local or remote operation is assured by a Local/Remote switch on the front panel of the amplifier. Also included with the Remotes Package is a safety interlock circuit for use with external safety switch interlocks. This circuit prevents the amplifier from going into operate mode unless the external connection is made.

A jumper plug is provided for cases where this functionality is not needed. The export classification for this equipment is EAR99. 