Test Equipment Description
IMU4000 Specifications
IMU4000 Coupling Decoupling Network
- Maximum AC voltage280V
- Maximum DC voltage300V
- Maximum EUT current16A
- Frequency rangeDC up to 60Hz
- Power frequency synchro16.7 up to 60Hz
- Coupling EFTL, N, PE, L+N, L+PE, N+PE, L+N+PE, direct
- Coupling CWGL-N, L-PE, N-PE, direct
Electric Fast Transient (Burst)
EXT-IMU4000 F (EFT 4kV)
- Voltage range0.25 up to 4.4kV
- Voltage amplitude into 50ohm0.125 up to 2.0kV
- Voltage amplitude into 1kohm0.24 up to 4.0kV
EXT-IMU4000 F5 (EFT 5kV)
- Voltage range0.25 up to 5.1kV
- Voltgae amplitude into 50ohm0.125 up to 2.55kV
- Voltage amplitude into 1kohm0.24 up to 4.8kV
COMMON EFT SPECIFICATIONS
- Source impedance: 50ohm
- Pulse front time at 50ohm : 5ns
- Pulse duration at 50ohm: 50ns
- Burst duration: 0.01 up to 30ms
- Burst repetition: 1 up to 1000ms
- Spike repetition frequency: up to 1MHz
- Polarity: Positive / Negative
- Programmable parameter ramps: voltage, spike frequency, burst duration
- Spike distribution: IEC burst pattern and Random
Control features
- User Interface7” :Colour touch panel
- Operating System: EMC PARTNER (EPOS)
- Communication Interface: Ethernet
- Accessory control interface: RS485
- Atmospheric measurement: Temperature, humidity, pressure (with accessory)
- BNC monitor ports: EUT plus IMPULSE voltage & current
- Trigger mode: Auto, manual, external
- Synchro source: EUT power, Impulse out, External
- Synchro on / off : 0° up to 360°