4 power lines, (2L+N+PE), (3L+PE),...
New
Typical Lead time: 4 - 6 Weeks
Warning: Last items in stock!
Availability date:
Voltage Rating | AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V);DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V);Test voltage: 3 kV DC, 2 sec |
Frequency Range | 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz) |
Standards Met | IEC 61000-4-6 |
RF Connector | BNC, 50 Ω |
Mains & EUT Connections | 4 mm, safety (Optional IEC 320 16A) |
Common Mode Impedance | 150 kHz to 26 MHz: 150 Ω ±20 Ω;26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω |
Current Rating | 32 Amps Maximum |
Application/Test Type | 4 mains AC power lines emissions testing up to 32 Amps (2L+N+PE), (3L+PE), optional (3L+N) |
Insertion Loss | Greater than 0.1 dB |
RF Input Voltage | Less than 30 V |
Decoupling of Common Mode Disturbance | Greater than 30 dB |
Voltage Division Factor | 10 dB +3 dB / -1 dB |
Dimensions | 6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm) |
Weight | 6.5 kg (14.3 LB.'s) |
IEC/EN 61000-4-6 specifies the design and performance of a range of coupling/decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq offers an extensive range of CDNs which fully comply with the requirements of the standard and provide a simple and reliable method of injecting RF energy into the equipment under test (EUT).