Specifications

Standards MetANSI/IEEE C62.41; IEC 61000-4-11; IEC 61000-4-12; IEC 61000-4-29; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-8; IEC 61000-4-9; EN 61000-6-1; EN 61000-6-2; ITU-T K.XX; UL 1741
Application/Test TypeCE Marking - Cover transient and power fail requirements according to international standards for immunity tests
Pulse voltage (open circuit)250 V - 7,000 V ± 10%
Impedance2 Ohm / 12 Ohm
Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse)
Pulse conforms to IEC/EN 61000-4-5
ParameterValue
Pulse current (short circuit)Max. 3,500 A ± 10%
CouplingAs per IEC 61000-4-5:Line to line with 2 ohm,Line(s) to ground with 12 ohm;As per ANSI/IEEE C62.41:Line to line with 2ohm,Line(s) to ground with 2ohm
Repetition time10ms - 9,999ms
Pulse repetitionmax. 0.5Hz (2s - 999s)
Phase synchronization0° - 360°, resolution 1° (16 - 500Hz)
Polaritypositive / negative / alternating
CouplingL, N, PE; all combinations
Phase synchronization0° - 360°, resolution 1°
Dips, Interrupts & Variations
Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
ParameterValue
Dips, Interrupts & VariationsAs per IEC/EN 61000-4-11,IEC/EN 61000-4-29 andIEC/EN 61000-6-1, -6-2
Test duration1 - 30,000 or endless, selectable
Test duration0:01min - 99:59min
Uvar with step transformer300V AC
Peak inrush current capability500 Amps
Burst (EFT) 5/50 ns
Pulse conforms to IEC/EN 61000-4-4
ParameterValue
Pulse amplitude200V - 5,500V ± 10%;100V - 2,750V ± 10% into 50ohm
Burst frequency0.1 kHz - 1,000 kHz
Polaritypositive / negative
Uvar with optional variacN/A
Ringwave 0.5 μs/100 kHz
Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
ParameterValue
Pulse voltage (open circuit)250 V - 6,000 V ± 10%
Switching timesUnder 5us into a 100ohm resistive load
Event time20us - 9,999s
Repetition time10ms - 9,999s
Test durationmax. 1 Hz (1 s - 999 s)
Pulse current (short circuit)Wave Shape
Impedance12 ohm and 30 ohm
PolarityPositive, negative
Pulse repetitionAutomatic, manual, external
Phase synchronization0° - 360°, resolution 1° (16 - 500Hz)
Phase synchronization0° - 360°, resolution 1°
CouplingL, N, PE; line to line and line(s) toground
Burst time0.10ms - 999ms
Dimensions19", 3HU
Telecom Surge
As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
ParameterValue
Test Voltage250 V - 7,000 V ± 10%
Energy Storage Capacitor20 uF
PolarityPositive, negative, alternating
Counter1 - 30,000 or endless, selectable
Front TimeAs per ITU and ETSI recommendations: 10 us ± 30%; As per FCC part 68, Pulse B: 9 us ± 30%; As per IEC 61000-4-5: 5 us ± 30%
Pulse DurationAs per ITU and ETSI recommendations: 700 us ± 20%; As per FCC part 68, Pulse B: 720 us ± 20%; As per IEC 61000-4-5: 320 us ± 20%
Output Current6 A - 175 A (short circuit) at 25 Ohm Output
Event TriggerAutomatic, manual, external
Repetition RateMax. 0.33 Hz (3 s - 999 s)
OutputsFor 2-wire T1/T2 with 25 ohm each & For 4-wire T1/T2/T3/T4 with 25 ohmeach
Weight25 kg's (55 Lbs)

Test Equipment Description

The EM Test UCS500N7 Multifunctional Transient Immunity Simulator includes everything necessary to conduct fully compliant tests at levels that go far beyond common test requirements.

Surge can be test up to 7.0kV either according to IEC/EN 61000-4-5 or ANSI/IEEE C62.41. The UCS 500N7 offers an integrated Ringwave module (optional) as per ANSI/IEEE C62.41 and IEC/EN 61000-4-12 for ringwave tests on mains supply lines.

The EM Test UCS 500N7 can be operated manually from the front panel or by remote via the built-in USB or GPIB interface. Fail inputs allow to control an ongoing test sequence based on the status of the DUT. Monitoring outputs (BNC) are offered for easy signal measurement and verification. Safety features such as interlock and warning lamp control are available.

Pre-programmed Standard Test routines allow highest user convenience. Still the UCS 500N7 offers the Quick Start test routine where parameters can be changed on-line during the test to evaluate the susceptibility level of an individual DUT, a most appreciated benefit for tests at development stage.

The EM Test UCS500N7 Multifunctional Transient Immunity Simulator is the most versatile tester to cover transient and power fail requirements according to international standards (basic and generic standards) and product/ product family standards with voltage capability of up to 7.0 kV. Apart from the IEC/EN 61000-4-5 standard for surge testing it also complies to ANSI/IEEE C62.41 for surge and ringwave testing.

The UCS 500N7 not only represents the most economic solution for full-compliant immunity tests and CE Marking but goes far beyond. Having a built-in CDN for single phase DUTs it can be extended for testing three-phase DUTs by means of an automatically controlled external coupling network up to 100A.

EM Test UCS500N7 Features:

  • Ultra-Compact Simulator up to 7.0kV
  • Surge Module for IEC/EN 61000-4-5 Edition 3
  • Burst Module for IEC/EN 61000-4-4
  • PowerFail Module for IEC/EN 61000-4-11
  • Ringwave Module for IEC/EN 61000-4-12 (optional)
  • Telecom Surge Module (IEC/EN 61000-4-5) optional
  • Magnetic field tests with optional accessories
  • Built-in single phase coupler 300V/16A
  • USB and GPIB-Bus for remote control
  • Manual operation from front panel
  • Monitor outputs for peak voltage and peak current
  • Fail inputs
  • External variac control 0-10Vdc
  • Control of external three-phase couplers

EM Test UCS500N7 Ordering Options:

  • UCS 500N7: Ultra compact simulator with EFT/N7, VCS/N7 and PFS/N7; 1ph CDN 300V AC/DC (p-n) / 16A (IEC & ANSI Cat.A & B)
  • UCS 500N7.1: Ultra compact simulator with EFT/N7, VCS/N7 and PFS/N7; 1ph CDN 300V AC/DC (p-n) / 32A (IEC & ANSI Cat.A & B)
  • UCS 500N7.2: Ultra compact simulator with EFT/N7, VCS/N7 and PFS/N7; 1ph CDN 400V AC/DC (p-n) / 16A (IEC & ANSI Cat.A & B) No module RWG/N7 possible with this unit!!! 
  • UCS 500N7.3: Ultra compact simulator with EFT/N7, VCS/N7 and PFS/N7; 1ph CDN 300VAC (L-N) / 32A (ANSI), can have RWG/N7 installed, unit will become 9HU high. RWG/N7 module to be ordered additionally
  • UCS 500N7.4: Ultra compact simulator with EFT/N7, VCS/N7, RWGN/7 and PFS/N7; 1ph CDN 400V AC/DC (p-n) / 16A (IEC & ANSI Cat.A & B)
  • UCS 500N7.7: Ultra compact simulator with EFT/N7 and VCS/N7 (IEC & ANSI Cat.B coupling), without built-in coupler! Application Voltage 690V(p-p) 