3ctest PFS Series Single Three-Phase Power Fail

New

  • 5.7 inch color Touch Screen
  • Full compliant test as per IEC 61000-4-11
  • Built-in multifunctional test module
  • Data acquisition of voltage and current
  • Programmable test procedures
  • Ethernet RJ45, PC remote control, test report documentation and print

Standard

  • IEC 61000-4-11
  • IEC 61000-4-34
  • GB/T 17626.11
  • GB/T 17626.34
  • EN 61000-4-11

More details

Request Quote/More Info

PDF Downloads

Test Equipment Description

3ctest PFS series single/ three-phase power fail simulator simulates voltage dip, interruption and variation which are caused by power grid and transformer devices due to malfunction or sudden large change of load. It is required to test this kind of phenomena to check whether electronic and electrical device can sustain safety operating condition. PFS series single/ three-phase power fail simulator is equipped with controllable semi-conductor switches with protection function as per IEC 61000-4-11/34,GB/T17626.11/34.

General Data
Display5.7 inch TFT touch screen
Power supply110V or 220V,±10%,50/60Hz(default AC 220V, 50Hz)
Fuse6A
Max. Power consumption300W
Memory spaceInfinite (PC)
Communication modeEthernet LAN、RJ45
Auxiliary interfaceD-sub 25p
External trigger inputBNC,5V TTL
CRO outputBNC,5V TTL
InputBNC,5V TTL
Synchronization45-65Hz, 20-500V between dotted terminal & undotted terminal 0-500V among dotted terminal, undotted terminal and case
Warning LED0-220VAC 10A/0-48VDC 3A Depending on external signal lamp
Safety circuitTest only can be started when it is closed
Failure testDisplay on LCD and interrupt the work at failure case
Working indicatorLED, LCD front panel display
Grounding connectionFlat ground line
EUT power injection5-core industrial plug
Output modeStandard 1m coaxial cable
Size19 inch 6U or 22U/35U cabinet
WeightApprox. 35Kg-150Kg
Temperature15–35℃
Humidity45%–75%
Air pressure86kPa–106kPa
Power fail test as per IEC 61000 - 4 – 11 & IEC 61000-4-34 for single/three phase AC including voltage dips, short interruption and variation
Technical Parameters
EUT max. Continuous current12A   (PFSxx10xxx series) 18A   (PFSxx16xxx series) 33A   (PFSxx30xxx series) 55A   (PFSxx50xxx series) 110A  (PFSxx100xxx series) 220A  (PFSxx200xxx series)
Withstand impulse currentProduct’s current no more than 50A: 500A, more than 50A: 1000A
ProtectionInternal over current, short circuit, over voltage, over heat, surge, burst, ESD protection Optional external accessories for Line in, Line out port
EUT max. Input voltageSingle phase 250VAC±5%, 50/60Hz±5%(300VDC optional) Three-phase : PFS38xxxx series: 420VAC, 50/60Hz±5%(300VDC optional) PFS45xxxx series: 480VAC, 50/60Hz±5%(300VDC optional) PFS69xxxx series: 720VAC, 50/60Hz±5%(300VDC optional)
EUT current and voltage measurementLCD display
Interruption level0%
Voltage interruption modeOptional one phase, two-phase or three-phase
Dip level0%-100%
Voltage dip modeLine to neutral Line to line PFSxxxxT1:GB/T17626.34 picture 3a, b/IEC61000-4-34:Figure3a、3b PFSxxxxT3:GB/T17626.34picture 3a, c/IEC61000-4-34:Figure3a、3c
Repetition rate0.3-9999 cycle or 5ms-9999ms
Duration5ms-9999ms
Test time1s-9999s
Rise and fall timeProduct’s current no more than 75A: 1-5us( standard resistance calibration) More than 75A: 1-50us(standard resistance calibration)
Voltage variation level
(for no more than 16A)
0-100%
Time for decreasing voltage
(for no more than 16A)
500ms-9999ms(50%-100%)or 1-5us(100 ohm load) 1000ms-9999ms(0%-100%)or 1-5us(100 ohm load)
Time for increasing voltage
(for no more than 16A)
500ms-9999ms(50%-100%) 1000ms-9999ms(0%-100%)
Time for reduced voltage
(for no more than 16A)
10ms-99999ms
Synchronization0°- 360°, 1° step or random
Trigger modeAutomatic, manual, or external
Load Capacity
Peak Impulse Capacity
Rated currentWithstand impulse current capacity
Current no more than 50A500A
50.1A~100A current1000A
Current more than 100AMore than 1000A
Simulator with rated current no more than 16A meets the load capacity specified in IEC 61000-4-11
Rated currentLoad current capacity
PFS 3810T1 PFS 3810T3V12A  AC/DC continuous current; 15A continuous 5s; 25A continuous 3s;
PFS 3816T1 PFS 3816T3V18A  AC/DC continuous  current ; 23A continuous 5s; 40A continuous 3s;
Standard Accessories
PFS test system, power cable, EUT supply cable, internet cable, factory test report, user manual