Frequency Range | 10kHz–400MHz |
RF Connector | Type N female |
Gain | GAIN (at maximum setting): 50 dB minimum GAIN ADJUSTMENT (Continuous Range) : 20 dB minimum |
RF Input Voltage | 1.0 milliwatt maximum for rated output |
Impedance | 50 ohms |
Input | 100-240 VAC, 50/60Hz, 500 watts |
Output | POWER OUTPUT @ 3dB COMPRESSION: Typical: 125 watts, Minimum: 100 watts POWER OUTPUT @ 1dB COMPRESSION: Typical: 85 watts, Minimum: 75 watts |
Flatness | FLATNESS: ±1.0 dB typical, ±1.5 dB maximum |
Dimensions | With cabinet: 50.3 x 15.5 x 55.1 cm (19.8 x 6.1 x 21.7 in) Without Cabinet: 48.3 x 13.2 x 55.1 cm (19 x 5.2 x 21.7 in) |
Weight | With Cabinet 18.5 kg (41 lbs) Without Cabinet 10.4 kg (23 lbs) |
The Amplifier Research 100A400A is a solid-state, selfcontained, air-cooled, broadband amplifier designed for applications where instantaneous bandwidth, high gain and linearity are required. Available in a stylish, contemporary cabinet for benchtop use or with cabinet removed for rack mounting.
The Amplifier Research 100A400A, when used with a sweep generator, will provide a minimum of 100 watts of RF power. Included is a front panel gain control which permits the operator to conveniently set the desired output level. The 100A400A is protected from RF input overdrive by an RF input leveling circuit which controls the RF input level to the RF amplifier first stage when the RF input level is increased above 0dBm. The RF amplifier stages are protected from overtemperature by removing the DC voltage to them if an over-temperature condition occurs due to cooling blockage or fan failure. The front panel indicates the operate status and fault conditions if an overtemperature or power supply fault has occurred. The unit can be returned to operate when the condition has been cleared.
All amplifier control functions and status indications are available remotely through the optional Remotes Package. The Remotes Package includes GPIB/IEEE-488 format, RS-232 hardwire and fiber optic, USB, and Ethernet. The bus interface connector is located on the back panel and positive control of local or remote operation is assured by a Local/Remote switch on the front panel of the amplifier. Also included with the Remotes Package is a safety interlock circuit for use with external safety switch interlocks. This circuit prevents the amplifier from going into operate mode unless the external connection is made. A jumper plug is provided for cases where this functionality is not needed.
The export classification for this equipment is EAR99.