  • 5.7 inch color touch screen 
  • Surge failure detection
  • Data acquisition of surge voltage and current 
  • Test scheduling function
  • With multifunctional modules
  • Can be internal single-phase AC 250V 16A;DC 250V 16A
  • Optional for External three-phase CDN and modules
  • Ethernet, RJ45, PC for remote control, test report documentation and print

More details

Request Quote/More Info

PDF Downloads

Test Equipment Description

The 3ctest CCS 500 is an intelligent multifunctional compact immunity (EMS) test system, as per all the requirements of international standards and product standards for transient pulse, surge and voltage dip, the test voltage is up to 5kV. CCS 500 is the option for full compliance immunity test as per the requirements of EU CE certification and CCC certification for single-phase devices. It can be optional to be built-in automatic single-phase coupling/decoupling network. Three-phase five-wire test can also be conducted by an external coupling network (up to 100A). You are provided with a variety of required accessories to meet the test requirements, such as power frequency magnetic field test.

General Data
Display5.7inch TFT color touch screenPower supplyAC 110V/220V,士10%, 50/60Hz,士5% (default AC 220V 50Hz)
Fuse6AMax power consumption200W
Memory spaceInfinite(PC)Communication modeEthernet, RJ45
Dimension(W*H*D)19inch/6UWeightApprox.35Kg
Temperature range15-35℃Humidity range45%-75%
Air pressure86kPa-106kPa 
EFT/burst test as per IEC 61000-4-4
Test voltage0.25kV-4.8KV(±10%)Source impedance50 ohm
PolarityPositive, negative, alternativeRise time5ns±30%,50 ohm load,1000 ohm load
Pulse waveform5/50ns,50 ohm and 1000 ohm loadPulse frequency0.1kHZ-1000kHz
Pulse duration50ns±30%,50 ohm loadBurst duration0.075ms-750ms
50ns-15/+100ns,1000 ohm loadTest duration1s-9999s
Burst cycle11ms-9999msSynchronization0°-360°, 1° step or random
Trigger modeAutomatic, manual or externalCDNOptional for internal single phase automatic CDN: AC 220V 16A Max 250V
SURGE as per IEC61000-4-5
Test voltage0.3kV-5kV (±10%)Test current0.15kA-2.5kA (±10%)
Voltage waveformFront time: 1.2us±30%, Time to half value: 50us±20%Source output impedance2 ohm
Current waveformFront time: 8us±20%, Time to half value:20us±20%Coupling capacitance9μF、18μF
PolarityPositive, negative, alternativePulse cycle5s-99s
(shortest depends on test voltage)
Coupling resistance10 ohm、0 ohm coupling resistor or customizedNumber of test1–999
Surge voltage and current peak detectionFront panel BNC output, surge voltage: 1000V:1V           Surge current :500A:1V          3 digits on displaySynchronization0° - 360°, 1° step or random
Trigger modeAutomatic, manual or externalCDNOptional for internal single phase automatic CDN: AC 220V 16A Max 250V
PFMF test as per IEC61000-4-8 with optional module MFT 400/1200 or VMT series
Magnetic field strengthTCXS 111 Single-turn coil: :1-100A/m (continuous) 100-400A/m (1-10s in short time)

TCXS 113 Single-turn coil :1-300A/m (continuous) 300-1200A/m (1-10s in short time)
THID<5%
Current waveform50Hz/60Hz sine waveOperating current range for short time120A-500A
Continuous operating current range1A-120ATest duration1-28800s
Waveform interval1-9999sCoil size1000*1000mm or others
Trigger modeAuto ,manual, externalCoil turnSingle/three turn
Coil shapeRectangle or othersOutput magnetic field strengthProgrammable setup
Pulse magnetic field test as per IEC 61000-4-9 with optional module PMC 1200
Output magnetic field range100 A/m-1200A/mWaveformRise time:6.4us±30%; duration: 16us±30%
Output current100A-2000APolarityPositive, negative, alternative
Synchronization0°- 360°,1°step or randomPulse cycle5-99s
(the shortest depends on test current)
Trigger modeAuto ,manual, externalCoil shapeRectangle
Number of test1-999Model of CoilTCXS 111
Coil size1000*1000mmOutput magnetic field strengthProgrammable setup
Coil turnSingle 
Power fail test as per IEC 61000 - 4 – 11 & IEC 61000-4-29 with optional module VVT or VMT series
EUT max. Voltage250V AC,220V DCEUT max. currentAC/DC 16A continuous current ; AC 20A continuous 5s;40A continuous 3s;500A impulse current
EUT current and voltage measurementBNC terminal: voltage 100:1, current 10A:1VDip level0%-100%(for VVT/VMT series) 0%,40%,70%,80%(for VVTxxxxSFseries)
Interruption level0%Dip and interruption interval5ms-9999ms
Dip and interruption duration0.1-9999 cycle or 1ms-9999msDip and interruption rise/fall time1-5µs (100Ωload)
Dip and interruption test duration1s-9999sTime of Voltage variation decreasing  500ms-9999ms(50%-100%) or 1-5us(100Ω load) 1000ms-9999ms(0%-100%) or 1-5us(100Ω load)
Voltage Variation level0-100%Duration after voltage variation decreasing10ms-99999ms
Time of Voltage variation increasing  500ms-9999ms(50%-100%) 1000ms-9999ms(0%-100%)Trigger modeAuto ,manual, external
Synchronization0°- 360°,1° step or random 

Models Selection
NameModelIEC 61000-4-4IEC 61000-4-5IEC 61000-4-8IEC 61000-4-9IEC 61000-4-11IEC 61000-4-29CDN single phase three wire
Combination wave surge simulatorCCS 500
EFT/Burst CDNEFTN 3816T      
Surge CDNSPN 3816T      
EFT/Burst and Surge CDNSEPN 3816T     
SEPN 3832T     
Power frequency magnetic moduleMFT 400      
MFT 1200      
AC voltage dips, short interruption and variation moduleVVT 2216S      
VVT 2216SD     
VVT 2216SV      
Power fail and Power frequency magnetic moduleVMT 2216S     
VMT 2216SV     
VMT 2216SVD    
Pulsed magnetic converterPMC 1200      
Standard Equipped