Viewed products
Up to 2.5 kV Surge Power Line Up to...
Meets MIL-STD-461 LISN Requirements...
New
Warning: Last items in stock!
Availability date:
Application/Test Type | Test levels as per FCC part 68 |
Coupling | Telecom ports: Tip to Ground, Ring to Ground, Tip and Ring to Ground Power ports 250V/16A: L toN, L to PE, N to PE , L+N to PE |
Polarity | pos / neg / alternate |
Output Current | 64A – 1,000A (power line) 20 – 200A per wire (surge A) |
Rise time | Less than 2 us |
Trigger of bursts | Automatic pulse release |
Telecom Surge As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations | |
Parameter | Value |
Test Voltage | 160V – 2,500V ± 10% (power line) 160V – 1,500V ± 10% (surge A) |
Outputs | 4 mm banana socket |
Dimensions | 19“ / 6HU, |
Weight | approx. 35kg |
The surge simulator EM Test TSS 500M2F generates high voltage transients as required by
FCC part 68.
Output voltage open circuit 160V – 2,500V ± 10%
Rise time tr < 2µs
Pulse duration td > 10µs
Output current short circuit 64A – 1,000A
Rise time tr < 2µs
Pulse duration td > 10µs ± 20%
Polarity Positive, negative or alternating
Counter select 1 – 30,000 or endless
Output voltage open circuit 160V – 1,500V ± 10%
Rise time tr < 10µs
Pulse duration td > 160µs
Short circuit output current 20 – 200A per wire
Rise time tr < 10µs
Pulse duration td > 160µs
Polarity Positive, negative or alternating
Output voltage open circuit 160V – 800V ± 10%
Rise time tr < 10µs Pulse duration td > 560µs
Short circuit output current 20 – 100A per wire
Rise time tr < 10µs Pulse duration td > 560µs
Polarity Positive, negative or alternating
Coupling
Telecom ports
Tip to Ground, Ring to Ground, Tip and Ring to Ground
Power ports 250V/16A
L toN, L to PE, N to PE , L+N to PE