Test Equipment Description

The Noiseken LSS-15SC is the lightning surge simulator conforming to "Surge Immunity Test Requirements" of IEC Pub. 801-5. This simulator is provided with a combination wave generator and is also provided with an AC/DC line injecting unit as a surge injecting unit.

Waveform Generator
The LSS-15SC is provided with a surge generator, namely a combination wave generator prescribed by "Surge Immunity Test Requirements" of IEC Pub. 801-5. The combination wave means a voltage waveform of 1.2/50 μ s when the circuit is open and a current waveform of 8/20 μ s when the circuit is closed.

Injecting Unit
Surge Immunity Test Requirements of IEC Pub. 801-5 prescribe several kinds of coupling/decoupling networks. The LSS-15SC is provided with an AC/DC line injecting unit.

(1) The AC/DC line injecting unit has a power capacity of AC240V 20A single phase and DC60V 20A for equipment under test. This unit is used to inject a combination wave to an AC/DC power line.

(Note) It is necessary to receive power from an external AC power supply or DC power supply.

Components of LSS-15SC
The LSS-15SC consists of Control Unit, Surge Generator and AC/DC Line Injecting Unit, which are set in the rack (1800mm in height x 555mm in width) with casters.

Note: It is necessary to receive power from an external AC power supply or DC power supply.

Components of LSS-15SC

The LSS-15SC Consists of Control Unit, Surge Generator and AC/DC Line Injecting Unit, which are set in the rack (1800 mm in height x 555 mm in width) with casters.


   Appearance of LSS-15SC
  1. Control Unit
    Use to control a surge output in accordance with settings of surge output conditions. Surge output conditions can be set on the front operating panel. It incorporates a high-voltage power supply for surge generation.

  2. Surge Generatos
    Used to generate combination waves.

  3. AC/DC Line Injecting Unit
    Used to inject a combination wave to an AC or DC power line. Injection mode can be set on the right side of the AC/DC line injecting panel.

Specifications and Performance of LSS-15SC
ItemsSpecificationsRemarks
Generated Surge Waveforms

Combination wave

  • Voltage surge 1.2/50 μ s (When output terminal is open.)
    Duration of wave front ±30%
    Duration of wave tail ±20%
  • Current surge 8/20 μ s (When output terminal is short-circuited.)
    Duration of wave front ±20%
    Duration of wave tail ±20%
 
Generated Surge Voltage and Current

Combination waves
HI: 500 ~ 15000V (1.2 / 50 μ s)
      250 ~ 7500A (8 / 20 μ s)
LOW: 500 ~ 7500V (1.2 / 50 μ s)
         250 ~ 35750A (8 / 20 μ s)

 (Note)
Output ImpedanceCombination wave 2.0 Ω ± 10%
PolarityPositive or negative (Change-over type)
AD/DC Line injectionPower capacity of EUTSingle Phase AC240V 20A MAX
DC 60V 20A MAX
 
Phase angle control of AC line0° ~ 360 °
Accuracy: ± for phase setting
(At AC 70V or over)
Infinitely Variable 30 steps
Reapeating cycle of surge generationMinimum repearing cycleCombination wave Approx. 20 seconds 
Time Setting range20 seconds ~ 59 minutes and 59 secondsAuto mode only
Counter setting range1~999999 (6-digit fighure, subtraction type) 
Remote controllerManual mode swtich, Auto mode switch, Start switch, Stop switch, High Voltage OFF Switch 
Main unit driving power supplyAC220V 50-60 Hz Approx. 600VA 
Dimensions(W) 555 X (H) 1800 x (H) 790 mm 

Note: When surge output voltage is below 500V, the surge waveform will not come within the tolerance prescribe by the "Surge Immunity Test Requirements" of IEC Pub. 801-5.