Viewed products
Order online now Voltage Range: 0.10...
Used
Warning: Last items in stock!
Availability date:
Standards Met | IEC/EN 61000-4-4 |
Repetition time | 0.1 to 400 Hz or 2.5 ms to 10 s or 1 to 500 period |
Coupling | Built-in Single Phase 250 Volts AC / 110 Volts DC and 16 Amps |
Test duration | Impulses per burst 1000 max Impulses per second 12000 max |
Burst (EFT) 5/50 ns Pulse conforms to IEC/EN 61000-4-4 | |
Parameter | Value |
Pulse amplitude | 0.10 - 4.5 kV |
Burst frequency | 1 Hz to 2 MHz |
Polarity | positive, negative, alternating |
Burst time | 0.01 to 999 ms |
The PEFT Junior test system, enables electromagnetic immunity testing in accordance with the standard IEC 1000-4-4 (IEC 801-4). The built in single phase mains filter enables coupling of EFT / Burst into the EUT mains supply with minimum disturbance to the general mains.