Viewed products
Internal automatic single phase CDN...
New
Typical Lead Time 2 - 4 Weeks
Warning: Last items in stock!
Availability date:
Supply Voltage | 85 ... 264 VAC, 150 VA, 50 / 60 Hz |
Standards Met | IEC/EN 61000-4-4 Ed. 1 + 2, IEC 61326, EN 61000-6-1, IEC 61850-3, EN 61000-6-2 |
Application/Test Type | Approval testing, Product development, Post design diagnostics, Industrial, Household |
Repetition time | 1s - 9999s |
Coupling | Built-in Single Phase AC 264 Volts / 16 Amps 50-60Hz, 10 Amps from 16 - 400 Hz; 125V/10A DC (Modes: L-GND, N-GND, PE-GND, LN-GND, LPEGND, NPE-GND, LNPE-GND) |
Test duration | continuous |
Burst (EFT) 5/50 ns Pulse conforms to IEC/EN 61000-4-4 | |
Parameter | Value |
Pulse amplitude | 1.0 to 7.3kV (6.6 kV at CDN Output) |
Burst frequency | 1 Hz … 110 kHz (Duration 0.01 - 999 ms) |
Polarity | positive / negative / alternate |
Burst time | 0.1 Hz - 400 Hz; 2.5 ms - 10 s; 1 period - 500 periods |
Dimensions | 450mm x 130mm x 570mm |
Weight | 14 kg |
The 3ctest EFT 500S series is the multifunctional test simulator for EFT/Burst with a built-in single phase coupling /decoupling network. It is designed to meet the requirements of electronic and electrical standards. Stable performance and good reliability make the EFT 500 an optimum standalone solution for both testing during development and final testing of products and sub-assemblies. With internal automatic single phase CDN, it is featured with good reliability, stable performance and easy use.
The EMC Shop offers on-site support for rentals and sales of EFT/Burst generators. Contact us for more information on the 3ctest EFT 500S.