Rent Haefely PIM 100 Combination Wave Impulse Module for IEC 61000-4-5 and ANSI C62.41 View larger

Rent Haefely PIM 100 Combination Wave Impulse Module for IEC 61000-4-5 and ANSI C62.41

Used

  • Floating high voltage output
  • Combination wave 1.2/50us - 8/20us
  • 7.4kV impulse voltage
  • 3.7kA impulse current
  • Impulse voltage & current monitors
  • Accurate phase angle synchronization
  • Meets standards:
    • UL 1449
    • IEC 61000-4-5
    • ANSI C63.4
    • And more!

More details

Typically In Stock

Request Quote/More Info

PDF Downloads

Specifications

Standards MetIEC 61000-4-5 Ed. 1 & 2 and ANSI C62.41 and C62.45
Pulse voltage (open circuit)0.2 – 7.4kV ±10% (1.2 us ±30% risetime)
Impedance2 Ohms
Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse)
Pulse conforms to IEC/EN 61000-4-5
ParameterValue
Pulse current (short circuit)0.1 – 3.7 kA ±10% (8 us ±20% risetime)
Coupling3 Phase - 32 Amps, 690 VAC
Pulse repetition10 seconds / 6 per minute
Polaritypos / neg
Phase synchronization1° steps
Test duration50 us ±20% (Voltage) ; 20 us ±20% (Current)
Dimensions45 x 20 x 57 cm

Test Equipment Description

Turnkey Rental Package Includes:

  • Haefely PSURGE 8000 Mainframe
  • Haefely PIM 100 Impulse Module
  • Haefely PCD 100 1PH/16A Coupling Decoupling Network
  • HV DC Bus cable 1m
  • Haefely Bus cable 0.5m
  • Earth bonding cable 1m
  • Earth bonding cable 0.25m
  • User Manual
  • Calibration Certificate

Haefely PIM 100 Module Description:

IEC 61000-4-5 and ANSI C62.41 describe a combination Wave or Hybrid generator with defined o pen AND short circuit waveforms. The Combination Wave is used to test AC and DC power systems. Safety is paramount with surge impulses. The PIM 100 High Voltage connections are all linked into the System Safety Concept which prevents high voltage plugs or cables from exposing operators to potentially lethal voltages. This concept is extended to Coupling/Decoupling Networks (CDNs) connected to the PIM 100 output. PIM 100 as part of the PSURGE 8000 Surge Platform System can be used together with Coupling/Decoupling Networks (CDNs) for superimposition of the impulse on AC and DC power lines. Single and three phase CDNs hav e multiplexed inputs, allowing up to 3 impulse modules to be connected. A full suite of test impulses can then be performed completely automatically and without the need to power down and reconnect the EUT. PSURGE 8000 Surge Platform can perform all the programming functions required to perform IEC and ANSI testing without the need of a control computer. Voltage and Current monitor circuits enable quick a nd easy verification of the impulse shape and amplitude. In addition, peak measurement circuits are used to help determin e EUT PASS/FAIL criterion. The integration in the WinFEAT&R control and report ing software package enhances an efficient setup and operation of this test system. Most importantly, the test load can be transferred to a computer freeing valuable resources.

Benefits:

International application – Specifically designed to meet and exceed the requirements of IEC, EN, and ANSI tests for power line applications.

Accurate Impulse Synchronization - The PIM 100 impulses can be applied to the AC power wave with 1° accuracy.

Safe and Easy - The interlocked HV section and the integrated controller allow your operators to test safely and easily.

Sturdy and Reliable – Careful component selection ensures that the PIM 100 will continue to operate un der the most strenuous testing regime.

Report Generation - The unit can automatically generate test reports without a computer. Add WinFEAT&R control and reporting software to collect and collate data in any format you like.

Faster completion of testing program - The PIM 100 connects to an EUT via either a PCD 100 or 130. Both have multiplexed inputs, enabl ing testing to continue with other pulses without having to remove power from th e EUT

Application:

  • Single & Three phase power line systems
  • IEC 61000-4-5 Edition 3 Power & Data lines
  • ANSI C62.41 Power lines
  • Many IEC & EN Product standards
  • Other international requirements for Hybrid impulses

Accessories:

PCD 100
Single phase CDN 16Aac & dc. Automatic coupling path switching. Two multiplexed high voltage inputs.
PCD 130
Three phase CDN 32Aac & dc Automatic coupling path switching. Three multiplexed high voltage inputs.
PCD 121
Manual coupling network for symmetrical data lines according to IEC 61000-4-5
PCD 126
Manual coupling network for asymmetrical networks according to IEC 61000-4-5
PIM 110
100kHz Ring wave tester according to ANSI C62.41 & IEC 61000-4-12
ADAPTERS
Single phase input & output adapters enable PCD 130 to be used for single phase applications
WinFEAT&R
Control and reporting software. Runs under windows 98, NT, ME, 2000, XP
Rack Mounting
Modules can be rack mounted for greater mechanical stability and mobility.

Associated EMC Test Equipment

30 other products in the same category: