Rent Thermo Keytek ECAT w/ E510A Module, 10kv Surge Combination Wave for IEC/EN 61000-4-5

Used

  • System Configuration(everything included):
    • E103 Controller (fiber-interface for remote control)
    • E510A Surge Simulator Module to 10 kV (IEC 61000-4-5, ANSI C62.41 Cat. B and UL 1449 at 5kA)
    • E4551A Single Phase Surge/EFT Coupler 250V rms (typ. 15 Amps)
    • Input voltage: 100V to 240VAC
    • Input Current: 3.5A at 100 V; 1.5A at 240 V

More details

In Stock

Request Quote/More Info

Specifications

Standards Met ANSI/IEEE C62.41 Cat. B and IEC 61000 4-5
Pulse voltage (open circuit)1.2/50µs, 0-10.1kV ±10% in 1 volt steps
Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse)
Pulse conforms to IEC/EN 61000-4-5
ParameterValue
Pulse current (short circuit)8/20µs, 0-5.05kA with 2 ohm effective source impedance, ±10%
Coupling1 PH / 15 (16) Amps
Repetition timeAdjustable from 300ms to 5s; 1ms resolution
Pulse repetition1 shot/18 seconds
Phase synchronization±15° with optional coupler/decoupler
CouplingModel E4551 - Single Phase 16 Amps
Test duration±20% Tolerance
Test duration1.0ms to 20ms; 1.0ms resolution or 1 to 200 pulses

Test Equipment Description

ECAT E510A Module Description:

The Keytek ECAT Simulator System with E510A plug in is a 10 kV surge gernerator that is IEC 61000-4-5 compliant.

  • 1.2/50us - 8/20us; IEC coupling
  • Surge pulses up to 10kV/5kA 
  • Single phase or three-phase coupler up to 100A (external options, separate) 
  • Standard test routines

How to Order the ECAT System:

  • Click "Add to Cart" above
  • Shipping Section - Select "Use My Account" - we ship this system freight to keep it upright. Indicate in the Notes section if you'd like us to facilitate shipment or if your logistics team will do so.
  • Checkout Accordingly
  • An EMC Shop representative will contact you with shipping estimates or logistics details.

About the Keytek ECAT System:

The Thermo Fisher Keytek ECAT Simulator systems are a sesoned favorite being used for electromagnetic Surge and EFT testing for more than 2 decades. The controller has an easy-to-use Windows based application software for quick implementation of test routines and standards, with automoatic report generation. A multi-level system interlock architecture provides maximum safety to keep first time users safe.

This used ECAT system is suitable for users looking to evaluate DUT in a precompliance environment for passing Surge and Burst (Electrical Fast Transient) immunity test standards such as IEC 61000-4-4, IEC 61000-4-5 and ANSI C62.41. The single phase, 15 amp coupling network is suitable for most commercial electronics and lower powered electronics.

ECAT Surge Simulator Configuration:

  • E103 Controller (fiber-interface for remote control)
  • E411 EFT/Noise Burst Simulator to 4.4 kV (IEC 61000-4-4)
  • E510A Surge Simulator to 10 kV (IEC 61000-4-5, ANSI C62.41 Cat. B and UL 1449 at 5kA)
  • E4551A Single Phase Surge/EFT Coupler 250V rms (typ. 15 Amps)
  • Input voltage: 100V to 240VAC
  • Input Current: 3.5A at 100 V; 1.5A at 240 V
  • User Manual
  • NIST Calibration Certificate